7219620.01 (1-04/15)
30
INST
ALLER Section
(en)
INSTRUCTIONS PRIOR TO INSTALLATION
The following notes and instructions are addressed to fitters to allow them to carry out trouble-free installation. Instructions for
lighting and using the boiler are contained in the ‘Instructions for Users’ section. Installation, servicing and running of domestic
gas-fired systems must be performed by qualified technicians, in compliance with current regulations.
Additionally, bear in mind the following:
• This boiler can be connected to any type of double- or single-pipe convector plate, radiator or thermoconvector. Design the
system sections as usual, though, bearing in mind the available flow-head at the plate, as shown in section 16.
• Do not leave any packaging (plastic bags, polystyrene, etc.) within the reach of children as they are a potential source of
danger.
• Initial lighting of the boiler must be carried out by an authorised Service Engineer, as indicated on the attached sheet.
Failure to observe the above will render the guarantee null and void.
ADDITIONAL PUMP WARNING
If an additional pump is used on the heating system, position it on the boiler return circuit. This will allow the correct operation of
the water pressure switch.
SOLAR WARNING
If the instantaneous (mixed) boiler is connected to a system with solar panels, the maximum temperature of the domestic hot water
entering the boiler must not exceed
60°C
.
Do not leave any packaging (plastic bags, polystyrene, etc.) within the reach of children as they are a potential source of danger.
9. INSTALLING THE BOILER
The template outline is shown in annex
"SECTION" C
at the end of this manual.
After deciding the exact location of the boiler, fix the template to the wall. Connect the system to the gas and water inlets present
on the lower bar of the template. Make sure the rear part of the boiler (back) is as parallel as possible to the wall (otherwise,
shim the lower part). Fit two G3/4 taps (flow and return) on the central heating circuit; these taps make it possible to carry out
important operations on the system without draining it completely. If you are either installing the boiler on an existing system or
replacing one, as well as the above, fit a settling tank under the boiler on the system return line in order to collect any deposits
and scale circulating in the system after flushing. After fixing the boiler to the template, connect the flue and air ducts, supplied
as accessories, as described in the following sections. Connect the siphon to a drain trap, making sure the slope is continuous.
Avoid horizontal stretches.
Do not lift the boiler exerting pressure on the plastic parts like the siphon and the flue turret.
Tighten the boiler water connections with care (maximum tightening torque 30 Nm).
9.1 CONTENTS OF PACK
• Template (see figure in annex "SECTION" C at the end of this manual)
•
Boiler support bar
•
Gas tap (
1
) and Water inlet tap (
2
)
• 8 mm expansion grips and pressure screws
ACCESSORIES
supplied on request: - heating flow/return taps and telescopic joint.
9.2 BOILER DIMENSIONS AND GAS WATER CONNECTIONS
The dimensions of the boiler and the relative installation positions of the water connections are shown in the annex
"SECTION"
C
at the end of the manual.
A
Condensate drain point
D
GAS inlet
B
Heating flow
E
Cold domestic water inlet / System filling tap
C
D.H.W. outlet (G1/2”) / Boiler heating flow (G3/4”)
F
Heating return
1
2
CG
_2
16
8
Summary of Contents for LUNA DUO-TEC+
Page 112: ...7219620 01 1 04 15 112 S E C T I O N A...
Page 118: ...7219620 01 1 04 15 118 S E C T I O N C 7218789 01 53 5 41 5...
Page 119: ...119 S E C T I O N C 7219620 01 1 04 15 53 5 41 5 A 168 5 53 5 41 5 A 168 5...
Page 120: ...7219620 01 1 04 15 120 S E C T I O N D 25 mm...
Page 123: ...123 S E C T I O N F 7219620 01 1 04 15...
Page 124: ...7219620 01 1 04 15 124 S E C T I O N G...
Page 126: ...7219620 01 1 04 15 126...
Page 127: ...127 7219620 01 1 04 15...