14. PARAMETERS SETTING
To programme the parameters of the boiler electronic board, proceed as follows:
•
Press
and
together and hold them down for 6 seconds until programme row “
P01
” appears on the display alternated
with the set value;
•
Press
to scroll the list of parameters;
•
Press
the value of the selected begins flashing, press
to change the value;
•
Press
to confirm the value or press
to exit without saving.
Further information concerning the parameters listed in the following table are supplied together with the required
accessories.
DESCRIPTION OF PARAMETERS
FACTORY SETTINGS
1.12
1.24
1.28
24
28
33
40
P01
Manufacturer information
00
P02
Gas used
00
= METHANE -
01
= LPG
00
P03
Hydraulic system
00
= instantaneous appliance
05
= appliance with external storage boiler
08
= heating only appliance
08
08
08
00
00
00
00
P04
Programmable relay 1 settings (See SERVICE instructions)
00
= no associated function
01
= relay contact closed with Room Thermostat demand (230V)
02
= relay contact closed with Remote Control demand (low voltage)
03
= system fill contact
04
= boiler faulty signal contact
05
= fan contact (kitchen fan)
06-07
= not used
08
= timed contact for enabling external DHW pump
09
= timed contact for enabling external DHW circulation pump via
DHW programming from remote control
10
= relay contact closed with DWH demand active
11 - 12 - 13
= not used
02
P05
Programmable relay 2 settings (See SERVICE instructions)
Same configurations as relay 1 - P04
04
P06
External probe input configuration
(See SERVICE Instructions)
00
P07..P09
Manufacturer information
--
P10
Heating setpoint setting OT / RT
(Remote Control - Open Therm / Room Thermostat 230V~)
00
=the temperature request is the Remote Control setpoint
01
=the temperature Request is the highest setpoint between Remote
Control and PCB
02
=the temperature request is the Remote Control setpoint. The Room
Thermostat enable the gas boiler operates
03
= the calculated setpoint depends on the origin of the request (PCB or
Remote Control):
a)PCB (Ambient Thermostat):
the setpoint is set by pressing the
+/-
buttons on the boiler control panel, after having first disconnected
the Remote Control from the boiler.
b)Remote Control:
the setpoint is set by modifying the “ULt”
parameter (see Room Unit accessory manual, chapter “INSTALLER
FUNCTIONS”)
c)Simultaneous request PCB - Remote Control
the higher setpoint
of the two requests is satisfied.
00
P11..P12
Manufacturer information
--
P13
Max. heating output
(0-100%)
100
100
100
80
86
80
77
P14
Max DHW output
(0-100%)
100
P15
Min. heating output
(0-100%)
00
P16
Maximum CH setpoint (°C)
00
= 85°C -
01
= 45°C
00
P17
Pump overrun time in heating mode
(01-240 minutes)
03
P18
Delay prior to new ignition in CH mode
(00-10 minutes) - 00=10 seconds
03
Summary of Contents for LUNA DUO-TEC+
Page 112: ...7219620 01 1 04 15 112 S E C T I O N A...
Page 118: ...7219620 01 1 04 15 118 S E C T I O N C 7218789 01 53 5 41 5...
Page 119: ...119 S E C T I O N C 7219620 01 1 04 15 53 5 41 5 A 168 5 53 5 41 5 A 168 5...
Page 120: ...7219620 01 1 04 15 120 S E C T I O N D 25 mm...
Page 123: ...123 S E C T I O N F 7219620 01 1 04 15...
Page 124: ...7219620 01 1 04 15 124 S E C T I O N G...
Page 126: ...7219620 01 1 04 15 126...
Page 127: ...127 7219620 01 1 04 15...