17. SERVICING AND PARTS REPLACEMENT
Always turn off the gas supply and allow to cool completely before commencing
any servicing (The appliance inlet “T” connector incorporates an isolating valve).
It is recommended that, at least once a year, the appliance is disconnected and the
fireplace opening checked and cleared of any debris.
This product uses fuel effect pieces and a burner compartment rear wall
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to eyes,
skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum. To
ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that you use a HEPA filtered
vacuum to remove any dust and soot accumulated in and around the fire before
and after working on the fire. When replacing these articles we recommend that
the replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and
may be disposed of at a tipping site licensed for the disposal of industrial waste.
Protective clothing is not required when handling these articles, but we recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or drinking.
!
Check that the appliance is clean and that soot or debris is not blocking the gaps
between the ceramic fuel effect pieces causing an imperfect flame.
!
Check that soot or debris is not impairing the electrode spark or pilot burner.
!
Check that soot or debris is not blocking any of the slots in the main burner.
!
After servicing, make sure that the ceramic rear wall and ceramic fuel effect
pieces are replaced correctly as described in the this guide.
!
Always test for gas soundness and spillage after servicing the appliance.
Page 39