T
6
Installation
6.14
Ciruit
of
the
hopp
er
transisto
r
The
b maXX® BM3400
devices have a chopper transistor, which is based on the following image.
b,int
R
b,ext
R
1D1
BaI
Ba−
+Uzk
−Uzk
Ba+
1C1
Figure 6.48: Chopper transistor
The activation of the internal chopper resistor (option) or of an connection to an external chopper resistor is
made via the connections BA-, Bal and 1C1.
In order to activate the chopper resistor, a wire link between Ba- and Bal is to be connected. At devices
according to type key V1 with internal chopper resistor the bridge is already integrated. In this case thed
internal chopper resistor and the chopper resistor monitoring cannot be deactivated.
The external chopper resistor must be connected between BA- an BA+.
At devices according to type key V2 chopper resistor monitoring is only active, if the internal chopper resistor
was activated with a bridge. At response of chopper resistor monitoring an error is released independent of a
possibly connected external chopper resistor.
NOTE
The chopper resistor monitoring is activated at recognition of a current flow by the internal
chopper resistor and remains active, as long as the 24V-supply is switched on. In case the
chopper resistor monitoring shall be deactivated after a changing over to an external chopper
resistor, then the 24V-supply must be switched off and the resetting must be operated without
the bridge, which was mentioned above.
106
Instrution
Manual
b
maXX®
BM3400
from
206
Do
ument
No.:
5.07013.03
Baumueller
Kamenz
GmbH
Summary of Contents for b maXX BM3400 Series
Page 1: ...E 5 07013 03 Instruction Manual b maXX BM3400 ...
Page 2: ......
Page 4: ......
Page 195: ...F Appendix F Index Instru tion Manual b maXX BM3400 195 Do ument No 5 07013 03 from 206 ...
Page 204: ......
Page 205: ... ...