T
rouble
sho
oting
8.5
T
•
DataRecError
(error in the module data record management) P0212
Error
no.
Meaning
Reaction
Troubleshooting
176–
177
Not assigned
—
—
178
Checksum error in EEPROM
PI
—
179
Not assigned
—
—
180
Incompatible SW
PI
The data in the EEPROM is invalid.
Save all data records.
181
Not assigned
—
—
182
Checksum error in the PSI
PI
Use another PSI module.
183
PSI is reset
PI
Save all data records.
184
PSI data is invalid
PI
The data in the PSI module is invalid.
Save all data records.
185
Autotuning tables invalid.
PI
Execute autotuning again
186–
191
Not assigned
—
—
•
PosCtrlError
(Error in the module Position controller) P0213
Error
no.
Meaning
Reaction
Troubleshooting
192
Position deviation dynamic
ad-
justable
Check the mechanical circumstances
and perhaps correct the controller
settings.
193
Position deviation static
ad-
justable
Check the mechanical circumstances
and perhaps correct the controller
settings.
194
Encoder 1 is used for position control
but is not active
PI
Activate encoder 1
195
Encoder 2 is used for position control
but is not active
PI
Activate encoder 2
196
Software-limit switch monitoring 1
active
—
Check the target position and the
travel range, which was released by the
limit switch.
197
Software-limit switch monitoring 2
active
—
Check the target position and the
travel range, which was released by the
limit switch.
Instrution
Manual
b
maXX®
BM3400
135
Do
ument
No.:
5.07013.03
from
206
Summary of Contents for b maXX BM3400 Series
Page 1: ...E 5 07013 03 Instruction Manual b maXX BM3400 ...
Page 2: ......
Page 4: ......
Page 195: ...F Appendix F Index Instru tion Manual b maXX BM3400 195 Do ument No 5 07013 03 from 206 ...
Page 204: ......
Page 205: ... ...