Cable
ontrol
voltage
supply
/
signals
D.13
T
D.10
Ciruit
mains
-
devie
device
cross section
1)
maximum length
connection to device
BM340X,
BM341X
4 x 1 to 2.5mm
2
(AWG 16 - 12)
1)
user-defined
with/without wire end ferrule
(plug-in terminal)
BM3422
4 x 8 to 16mm
2
(AWG 16 - 12)
1)
user-defined
with/without wire end ferrule
(plug-in terminal)
1)
Possible cross section: For UL conform machines/installations you must use UL certified circuit cables.
D.11
Ciruit
devie
-
moto
r
device
cross section
1)
maximum length
2)
connection to device
BM340X,
BM341X
4 x 1 to 2,5mm
2
(AWG 16 - 12)
2)
max. 50m
flexible cable without wire end fer-
rule (plug-in terminal)
BM3422
4 x 8 to 16mm
2
(AWG 16 - 12)
1)
max. 50m
with/without wire end ferrule
(plug-in terminal)
1)
Possible cross section: Use a screened circuit line, shield coverage
>
85%. The installing of the cables is
user-defined. For UL conform machines/installations you must use UL certified circuit cables.
2)
Only for Baumüller cables with this maximum length and by usage of a Baumüller mains filter you can
assume, that the limits of the EMC regulations are complied with.
D.12
Cable
ontrol
voltage
supply
/
signals
device
cross section
1)
maximum length
2)
connection to device
BM34XX
≤
0.5mm
2
user-defined
without wire end ferrule (plug-in
terminal)
1)
The laying of the cables is user-defined
2)
Any kind of cable can be used, the length of the cable does not influence the compliance to the EMC
regulation.
Instrution
Manual
b
maXX®
BM3400
189
Do
ument
No.:
5.07013.03
from
206
Summary of Contents for b maXX BM3400 Series
Page 1: ...E 5 07013 03 Instruction Manual b maXX BM3400 ...
Page 2: ......
Page 4: ......
Page 195: ...F Appendix F Index Instru tion Manual b maXX BM3400 195 Do ument No 5 07013 03 from 206 ...
Page 204: ......
Page 205: ... ...