2.1.3 Machine Setup Parameters
Table 3. Machine Setup Parameter List
P20: Units of Measurement
This selection specifies the unit of measurement used to
display all lengths. Inches (SAE) is the default selection.
Available choices are Meters (measurement displayed in cm)
and Inches (measurement displayed in inches and tenths of
inches).
P21: Language
This selection specifies the Language used to display
fault messages. Available choices are ENGLISH,
DEUTSCH, and CODES, see Tables 1618, Error Message
Translation. English is the default selection.
P22: Network Address
This selection specifies the unit address used for
Network communication. Available choices are 0 through
255. Address 0 is the default selection. Network functions
are not available in software version 2.6.0
P23: Pause
P24: Network Enable
Network components must be installed and enabled in
Maintenance Mode. Enable Network by selecting 1.
Disable network by selecting 0.
#
Function
Type
Variable
Displayed
P20
Units of Measure
Setup Variables
Adjustable
Inches, Meters
P21
Language
Setup Variables
Adjustable
English, German, Codes
P22
Network Address
Setup Variables
Adjustable
0-255
P23
Pause
Setup Variables
Adjustable
1 or 0
P24
Network
Setup Variables
Adjustable
1 or 0
P25
Easy
Setup Variables
Adjustable
1 or 0
P26
Software Version
Machine Configuration
Fixed
V X.X.X
P27
Machine Type
Machine Configuration
Fixed
Set at Factory
P28
Serial Output Type
Machine Configuration
Fixed
Off, Display, or Network
P25: Easy Mode
Enable Easy Mode by selecting 1. Disable Easy Mode
by selecting 0.
Easy Mode has two sheet control methods, Easy setup or
Continuous cycle. Easy setup will run any job with a 1 inch
sheet gap. The sheet gap display contains 3 dashes and the
Suction Length bar graph is turned off.
In Continuous cycle setup, the suction cycle is determined by
the sheet gap setting, sheet length setting and the suction
length setting. Sheet error detection methods are turned off.
P26: Hardware and Firmware Version
This selection shows the hardware and firmware
versions of the unit. The left side of the display shows logic
board type. The right side of the display shows the firmware
version (2.X.X).
P27: Machine Type
This selection, in maintenance mode, shows the selected
machine configuration.
P28: Serial Output Type
This selection, in maintenance mode, shows selected
serial output type.