TP10313
PAGE 12
1.4 Keypad Buttons with Selection Indicators
18) Show Output Count
19) Show Batch Count and Number of Batches
20) Show Current Rate
21) Show Input Count
22) Learn Mode
23) Make Ready Mode
1.5 Keypad Buttons for Selection Adjustment
24) Gap Minus
25) Gap Plus
26) Suction Length Minus
27) Suction Length Plus
28) Batch Preset Minus
29) Batch Preset Plus
30) Counter Setup Mode
31) Machine Setup Mode
32) Batching Time Minus
33) Batching Time Plus
34) Network Job Mode
35) Reset
36) Potentiometer Speed adjustment
2.1 Machine Setup/Diagnostic Mode
Pushing this key puts the controller in machine setup
mode.
Machine setup mode provides a method to view and
optionally change operating parameters for the controller.
The decimal points in the large display (1) will move from
side to side to indicate that various parameters may be
changed. In this mode, the small display gives the selected
parameter number, while the large display (1) shows a
parameter value. The suction length display (3) is disabled.
Parameter Group Selection
The plus and minus keys are used to select the various
parameter groups: machine setup parameters, machine
monitor parameters, machine diagnostic parameters, knife
status parameters, and machine usage parameters.
Parameter Selection within a Group
If the large display (1) decimal points are moving, this
set of minus and plus buttons will select the machine
parameters within each group, see tables 1-6.
Select Parameter Adjustment
If the large display (1) decimal points are moving, this
set of minus and plus buttons will move through the set of
values for the selected parameter, see tables 16.
+
+
+
2.0 Run Mode Functions
After turning on the main switch, thecontrol automati-
cally runs a self test. During this self test all displays and
indicator lights come on for approxmately 4 seconds. After
a successful self test, the display reverts to the previous
count screen active before power shutdown. In this mode,
various job parameters can be displayed on the large display
(1) and the small display (2) shows the gap length. The
suction length display (3) is active in this mode and shows
the suction length as a percentage of sheet length.
The DCT500 mode select keys perform the same
function in all modes, except Counter Setup. This allows a
user to quickly switch between the operating modes on the
counter. Select Make-Ready is not a mode unto itself, but
rather is a modifier to all modes.
During the self test operation, do not press any
button. Pressing of a button will cause an error
message to appear in the main display.
!