TP10313
PAGE 22
5.3 Batch Output Time
This parameter, accessible in the Batch Setup mode,
specifies the output duration or delay that will be used when
the Batch Count Down reaches zero.
Available ranges are determined by the Batch Output Type
selected. The Table below shows the ranges for each output
type.
5.4 Sheet Length
This parameter, accessible in the Batch Setup mode,
specifies the length of the paper that will be fed into the
machine.
Available range is 6.0 to 59.0. 6.0 is the default
selection.
5.5 Gap Length
This parameter is accessible in Run mode and Learn
mode and specifies the length of gap to use between sheets
of paper that are fed into the machine.
Available range is 0.2 to 98.0. 2.0 is the default selec-
tion.
5.6 Suction Length
This parameter is accessible in Run mode and Learn
mode andspecifies the suction length used on a sheet of
paper that is fed into the machine.
Available range is 5% to 50% in 5% increments. 30% is the
default.
Output
Delay
Duration
Type
Min. Time Max. Time Min. Time
Max. Time
Feed
Not applicable
0.0 Sec.
9.9 Sec.
Table
0.000 Sec.
1.000 Sec.
100 ms
Delivery
0.000 Sec.
1.000 Sec.
25 ms
Speed
Not applicable
0.00 Sec.
5.55 Sec.
Table 15. Output Delay and Duration