Description
Password level /
BCP command
Totaliz.P- overflow
value set
Setting the overflow value of the negative
part counter
L 4
VPNOS
CPU max.recorded
temperature
Maximum recorded CPU temperature
L 6
CPUMX
CPU min.recorded
temperature
Low recorded CPU temperature
L 6
CPUMN
Calibration offset
register 0
Calibration offset register 0
L 6
COFR0
Calibration gain
register 0
Calibration gain register 0
L 6
CGAR0
Calibration gain
register 1
Calibration gain register 1
L 6
CGAR1
Calibration gain
register C
Calibration gain register C
L 6
CGARC
7.6.13
Process data
menu
The following menus are only available as an BCP command in the
command input of the BCP software:
Menu
Description
Password level /
BCP command
Set value for
Digital output 1
Setting the value for the Digital output 1
L 0
OUT1S
Set value for
Digital output 2
Setting the value for the Digital output 2
L 0
OUT2S
F.rate f.scale in
chosen units
Flow rate / scale end value in selected unit
of measure
L 0
FRFSN
Flow rate value in
percentage
Flow in percent
L 0
FRVPC
F.rate in
perc.without cut-off
Flow in percent without cut-off
L 0
FRVPX
F.rate in
binary.without cut-
off
Flow in binary representation without cut-
off
L 0
FRVBX
F.rate value in unit
of measure
Flow rate in selected unit of measure
L 0
FRVTU
Totaliz.T+ read
value
Reading out the positive total counter
L 0
VTTPV
Operation
Menu navigation > Process data menu
05.03.2020
Flow sensor PF55S
90