WARNING!
Danger due to leaking system
Leaks in the system may occur when the flow sensor is
installed within a piping system. These leaks can lead
to a variety of different dangers.
The following must be observed when installing the
flow sensor:
–
The inner diameter of the seals is always equal to
or greater than the inner diameter at the connection
of the pipeline.
–
Seals must always be checked for damage and
cleanliness.
–
Seals must always be properly installed.
CAUTION!
Short circuit of the measuring signal due to incor-
rect sealing compound
If impermissible sealing compounds are used, an elec-
trically conductive layer can form on the inside of the
measuring tube of the sensor. As a result, short circuits
of the measuring signal are possible.
–
Never use electrically conductive sealing com-
pounds such as graphite.
2.14 Safety guidelines for maintenance and resolving faults
WARNING!
Risk of injury due to improper maintenance
Improper maintenance can result in serious injuries and
considerable material damage.
–
Always ensure that all previous maintenance work
has been carried out and completed in accordance
with the information and instructions set out in this
manual and the associated circuit diagrams.
–
Ensure that nobody is in the hazard zone before
commencing maintenance.
–
Maintenance must only be carried out by personnel
trained and authorized by the owner.
–
Personnel must have read and understood this
operating manual.
–
Personnel must follow the instructions in this
operating manual.
–
Personnel must have the necessary specialist
skills for such maintenance.
Tightness of the piping system
Improper maintenance
Safety and responsibility
Safety guidelines for maintenanc...