PCD41
38
www.baumer.com
5.1 Two-state balancing
a) Standard two-point alignment
In a standard alignment an initial value and a inal value are assigned
to the analog value.
Prior to the alignment, enter the following settings in programming
ield 3: line 41 = 0; in line 26 the offset.
Access programming ield using
.
Enter code or skip with key
.
Actual measured value
Indicated in the display for 1 s, then followed by
the assigned value. Press key
.
Peak memory
Indicated in the display for 1 s, then followed by
the assigned value. Press key
.
Minimum position value alignment
Indicated in display for 1 s, then followed by the
assigned value. Press key
.
Value is lashing.
Key
= access decade
Key
= enter numeral
Key
= acknowledge
Key
= reset to „000000“
Key
= programming operation inalized
Example:
1 x
key, 1 x
key
Acknowledge by key
.
Result: initial value „10“
Press key
.
Maximum position value alignment
Indicated in the display for 1 s, then followed by
the assigned value. Press key
.
Value is lashing.
Key
= access decade
Key
= enter numeral
Key
= acknowledge
Key
= reset to „000000“
Key
= programming operation inalized
Example:
to „000000“ using key
.
2 x key
, 5 x key
Acknowledge by key
Result: inal value „500“
Key
= back to operating mode.