26
Operating Manual for
BAUER Plug & Play Separator System
S
7.10.5
Manual operation with clear effluent pump:
The operation mode
„manual operation with clear effluent pump“ requires that all compo-
nents of the system must be switched on by hand. In the manual operation the overflow
must be opened, so that the excessive liquid manure can run off and the pressure in the
inlet does not rise. If the pressure in the inlet is too high, the pressure sensor can be
damaged. In manual operation the air pipe has to be mounted and the
1 ½”ball valve in
the inlet t piece must be opened. In the operation mode
„manual operation with effluent
centrifugal
pump“ a centrifugal pump pumps off the effluent. In order that the effluent can
be pumped off, the gate valve 4
“of the effluent pipe must be closed and the 3“ball valve
in the stand must be opened (see chapter 7.10.5.1). The system can be started after a
starter cake has built up (starter cake built up chapter 7.8).
Manual operation with clear effluent pump switch and lever position:
Gate valve for effluent closed, limit switch active:
“closed”
Ball valve 3” open (is located on the base frame):
“open”
Operation choice switch (on electrical cabinet):
„HAND“
Feed pump switch( remote control):
“FORWARD”
Separator switch ( remote control):
„FORWARD“
Overflow open
“open”
Figure 22 lever and switch position in manual operation with clear effluent pump
Gate valve closed
Limit switch active
OPERATION switch on electr.cabinet:
AUTO OFF HAND
FEED PUMP
REVERSE OFF FORWARD
SEPARATOR
REVERSE OFF FORWARD
Ball valve 3“ open