18
Operating Manual for
BAUER Plug & Play Separator System
S
Figure 9 electrical cabinet
Main switch of the electrical switch cabinet
Set main switch on the
electrical cabinet
to position
“ON/1” = vertical
Check direction of rotation:
Check the direction of rotation of the separator screw using the phase monitoring relay “1F2” in the
switch cabinet. The screw must run counterclockwise as seen from the press head.
Direction of rotation correct: Indicator light is on (steady) see figure 10
Direction of rotation incorrect: Indicator light not lit Swap lines L1 and L2
Press reset button 2x (please refer figure 13)
Bridging switch for break-through-control
For starting the unit, the break-through-control can be bridged manually
(Switch Position „ON“). After
the plug has been built and the flaps are in working position, the bridging can be ended (Switch Po-
sition „OFF), after that, the break-through-control is active.
Figure 11 Bridging switch for break through control
Indicator light
light
ELECTRICAL CABINET
MAIN SWITCH
Figure 10 phase monitoring relay
Figure 10 phase monitoring relay
1F2
Bridging switch
for Break-through control
OFF - ON
Figure 8 electrical cabinet
main switch
DIRECTION OF ROTATION
OK
OPÉRATION
OK
RESET
OPERATION
AUTO - 0 - HAND
SETPOINT PRESSURE
0,1-0,3bar
PUMPSPEED IN MANUAL
OPERATION
5-80Hz
HOUR METER
HELIXPUMP
BREAKTROUGHT SWITCH BRIDGING
OFF - ON
HOUR METER
SEPARATOR
PRESSURE SENSOR BRIDGING
OFF - ON