28
Operating Manual for
BAUER Plug & Play Separator System
S
8
PROBLEMS – TROUBLESHOOTING
NOTE
For troubleshooting the individual components of the Plug & Play Separator Sys-
tem, such as the separator, feed pump, discharge pump and control; please see
the enclosed operating manuals of the respective components.
WARNING
Troubleshooting should only be performed by appropriately qualified
personnel.
Geared motor switches off - Motor protection tripped:
Motor protection separator =
5F1
Motor protection clear effluent pump =
5F2
Motor protection conveyor belt =
5F3
Motor protection oscillator =
6F1
Motor protection external fan Helix
6F2
Motor protection frequency inverter / Helix = 7F1
The motor switches off when the permissible power consumption of the respective motor has been
exceeded.
System pressure set point was adjusted incorrectly:
When starting the system in automatic mode the feed pump does not start
no system pressure
adjusted
The feed pump switches off after a few minutes
target pressure set too low
The feed pump conveys too much material (Separator breaks through)
target pressure set too high
Adjusting the pressure set point see chapter 7.9 pressure adjustments
Main switch on electrical switch cabinet
is switched off
Main switch of the electrical switch cabinet vertical
Turn to “ON”/1 (please refer fig.25)
Power network connection does not work:
The cabinet is electroless
„Reset“-lamp does not light up
„Operation OK“ lamp does not light up
Frequency inverter does not start up
Check the supply line for correct connection and proper condition
Figure 24 motor protection switches
2F1
5F1
5F2
5F3
6F1
ELECTICAL CABINET
MAIN SWITCH
OFF
ON/1
Figure 25 electrical cabinet main switch
6F2
7F1