20
Operating Manual for
BAUER Plug & Play Separator System
S
Figure 13 reset button / fault lamp
Clear the stored faults
Press the RESET button on the front side of the switch cabinet to clear the stored faults
Fault light
goes out.
(please refer fig 13)
Check function of each component
Set the
OPERATION
choice switch on the front of the switch cabinet to
“
HAND
”
(please refer fig.14)
Press the switches of the respective components (separator, feed pump; clear effluent pump;
conveyor belt (if available), on the remote control (please refer fig.15) to check the function:
Figure 14 OPERATION SWITCH
Figure 13
OPERATION choice
AUTO OFF HAND
RESET fault lamp
Figure 15 remote control
DIRECTION OF ROTATION
OK
OPERATION OK
RESET
OPERATION
AUTO
– O -- HAND
BREAKTROUGHT SWITCH
BRIDGING
OFF - ON
SETPOINT PRESSURE
0,1
– 0,3BAR
PUMP SPEED
IN MANUAL OPERATION
5-80Hz
HOUR METER
HELIXPUMP
HOUR METER
SEPARATOR
PRESSURE SENSOR BRIDGING
OFF - ON