Reverse Osmosis Drinking Water System

Installation Instructions & Owner’s Manual

3 Stage 50 GPD

Model: GRO1025-5-3F

Содержание GRO1025-5-3F

Страница 1: ...Water Technologies Water Technologies Water Technologies Reverse Osmosis Drinking Water System Installation Instructions Owner s Manual 3 Stage 50 GPD Model GRO1025 5 3F ...

Страница 2: ...stem and Faucet Diagrams Page 6 Source and Drainwater Saddle Valve Page 7 Activation Troubleshooting and Maintenance Page 8 Warranty Information Page 9 Your Water Test Hardness gpg Iron ppm pH number Nitrates ppm Manganese ppm Sulphur yes no Total Dissolved Solids ...

Страница 3: ...o twelve months depending on the quality of the feed water supply CAUTION DO NOT USE THIS SYSTEM WHERE THE WATER IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY THIS SYSTEM IS FOR USE ON POTABLE WATER ONLY SOURCE WATER EXCEEDING CHEMICAL PARAMETERS REQUIRES PRETREATMENT CONDITIONS FOR OPERATION Source water Supply TFC Community Private Non Chlorinated System Pressure 30 100psi Temperature 4 38 C...

Страница 4: ... system will produce a faster flow at the faucet with the shortest tubing run from tank to faucet Preparation Fittings and Tubing All tubing is individually labeled and colour coded for ease of installation 1 4 Black Connects the feed water valve to the RO pre filter 3 8 White Connects the RO membrane product port to the storage tank 1 4 Orange Connects the membrane brine port to the drain connect...

Страница 5: ...t guide into the pilot hole Push down gently on the drill motor to apply light pressure to the porcelain surface Start the drill motor turning as slowly as possible After the initial cut has started motor speed may be gradually increased The cut may require three to four minutes to complete Going faster could result in excessive chipping This saw is used to cut the porcelain only Be sure a complet...

Страница 6: ...r valve to the RO pre filter 3 8 White Connects the RO membrane product port to the storage tank 1 4 Orange Connects the membrane brine port to the drain connector 3 8 Blue Connects the postfilter to the faucet Air Gap Faucet Non Air Gap Faucet 1 4 line membrane to air gap 3 8 line air gap to drain 3 8 Blue 1 4 Black 1 4 Orange 3 8 White ...

Страница 7: ...dle to the copper pipe Tighten the brass clamp screw with a 7 16 wrench Do not crush the tubing Do not over tighten the clamp The clamp should be secure and resist a slight twisting force Turn the saddle tapping valve clockwise until the needle fully pierces the tubing and the valve seats For maximum flow back the handle out all the way Adjust as required Turn on the cold water supply Check the sa...

Страница 8: ...n on the system and inspect for leaks 7 Drain the first tank of water after changing the filters before drinking When the membrane is changed drain the first two tanks of water before drinking Problem Reason Solution Water has offensive odor or taste Carbon post filter is depleted Drain storage tank and replace post filter Filters are depleted Replace filters and clean system Not enough water pres...

Страница 9: ...ervice life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply to any part of the Greenway RO Drinking Water System that is damaged because of neglect misuse alterations accident misapplication physical damage or damage caused by fire acts of God freezing or hot waters or similar causes Co...

Страница 10: ...Water Technologies Water Technologies Water Technologies Manuel d installation et d utilisation Système d osmose inverse pour eau potable 3 phases 50 GPD Modèle GRO1025 5 3F ...

Страница 11: ... Page 6 Robinet vanne à étrier pour les eaux usées et potables Page 7 Mise en service guide de dépannage et entretien Page 8 Renseignements concernant la garantie Page 9 Votre analyse d eau Dureté gpg Fer ppm Indice du pH number Nitrates ppm Manganèse ppm Soufre yes no Matières dissoutes totales ...

Страница 12: ...is selon la qualité de l eau d alimentation MISE EN GARDE N UTILISEZ PAS CE SYSTÈME OÙ L EAU EST MICROBIOLOGIQUEMENT DANGEREUSE OU DE QUALITÉ INCONNUE CE SYSTÈME EST POUR UNE UTILISATION AVEC DE L EAU POTABLE SEULEMENT L EAU POTABLE QUI EXCÈDE LES PARAMÈTRES CHIMIQUES DOIT SUBIR UN PRÉTRAITEMENT CONDITIONS POUR LE FONCTIONNEMENT Alimentation en eau potable TFC Communauté Privé Non chloré Pression ...

Страница 13: ...robinet avec un tronçon de tuyauterie court du réservoir au robinet Préparation Raccords et tubes Toute la tuyauterie est individuellement étiquetée et comprend un code de couleur pour faciliter l installation 6 35 mm 1 4 po noir Relie la soupape pour l eau d alimentation au pré filtre de l OI 9 52 mm 3 8 po blanc Relie le port de la membrane de l OI au réservoir de stockage 6 35 mm 1 4 po orange ...

Страница 14: ...ur le moteur de la perceuse afin d appliquer une légère pression à la surface de la porcelaine Mettez en marche la perceuse à la plus basse vitesse possible Lorsque la découpe initiale a débuté vous pouvez augmenter graduellement la vitesse de la perceuse Cette opération de découpe pourrait prendre de 3 à 4 minutes Découper plus rapidement pourrait provoquer des éclats excessifs Cette scie est uti...

Страница 15: ... stockage 6 35 mm 1 4 po orange Relie le port de la membrane à saumure au raccord de purge 3 8 9 52 mm 3 8 po bleu Relie le post filtre au robinet Robinet avec coupure anti retour Robinet sans coupure anti retour Tube 6 35 mm 1 4 po pour conduite de la membrane à la coupure anti retour Tube 9 52 mm 3 8 po à partir de la coupure anti retour à l égout 9 52 mm 3 8 po bleu 6 35 mm 1 4 po noir 6 35 mm ...

Страница 16: ...anne à étrier au tube de cuivre Serrez la vis de serrage en laiton avec une clé de 11 11 mm 7 16 po N écrasez pas le tube Ne serrez pas trop le serre joint Celui ci devrait être sécuritaire et résister à une légère pression lorsque tourné Tournez le robinet vanne à étrier dans le sens des aiguilles d une montre jusqu à ce que l aiguille perce entièrement le tube et le siège de la vanne Pour un déb...

Страница 17: ...pour des fuites 7 Après avoir changé les filtres et avant de boire l eau videz le premier réservoir d eau Lorsque la membrane est changée videz les deux premiers réservoirs d eau avant de boire l eau Problème Raison Solution L eau a une odeur ou un goût désagréable Le post filtre à charbon est usé Videz le réservoir de stockage et remplacez le post filtre Les filtres sont usés Remplacez les filtre...

Страница 18: ...ne est uniquement garantie si les conditions requises pour l eau d alimentation sont remplies La garantie ci dessus ne s appliquera pas à toute pièce du système d OI pour eau potable de GreenwayMD qui est endommagée par la négligence une mauvaise utilisation une modification un accident une mauvaise application des dommages physiques ou des dommages causés par le feu les catastrophes naturelles de...