5-3
Cycle and Control Value Programming
Operator Manual
920512-768
TAG #
TAG #
920-5
Rev. 1
M
12
1
2
3
4
ADJUS
1 TO
11
6 TO
11
5
11
WASH 2 (OPTIONAL)
RINSE
FINAL RINSE
PURE WATER RINSE
DRYING (OPTIONAL) or
VAPOR EXHAUST
RECIRCULATED
NON-RECIRCULATED
RECIRCULATED
NON-RECIRCULATED
------
02:00
00:35
03:00
00:35
15:00
160°F (71°C) NON-GUARANTEED
------
185°F (85°C) GUARANTEED
185°F (85°C)
MAXIMUM 212°F (100°C)
ACID
RINSE
RINSE
RINSE
FLOOR NOT TILTED
2 oz/gal (16 ml/l)
------
------
------
------
HW
HW
HW
PW
------
85%
------
85%
85%
------
RECIRCULATED
NON-RECIRCULATED
RECIRCULATED
NON-RECIRCULATED
------
02:00
00:35
03:00
00:35
15:00
160°F (71°C) NON-GUARANTEED
------
185°F (85°C) GUARANTEED
185°F (85°C)
MAXIMUM 212°F (100°C)
ACID
RINSE
RINSE
RINSE
FLOOR NOT TILTED
2 oz/gal (16 ml/l)
------
------
------
------
HW
HW
HW
PW
------
85%
------
85%
85%
------
RECIRCULATED
NON-RECIRCULATED
RECIRCULATED
NON-RECIRCULATED
-
08:00
00:35
02:00
00:35
10:00
160°F (71°C) NON-GUARANTEED
------
185°F (85°C) GUARANTEED
185°F (85°C)
MAXIMUM 212°F (100°C)
ACID
RINSE
RINSE
RINSE
TILTED FLOOR
2 oz/gal (16 ml/l)
------
------
-
------
HW
HW
HW
PW
------
85%
------
85%
85%
------
RECIRCULATED
NON-RECIRCULATED
RECIRCULATED
NON-RECIRCULATED
------
06:00
00:35
02:00
00:35
10:00
160°F (71°C) NON-GUARANTEED
------
185°F (85°C) GUARANTEED
185°F (85°C)
MAXIMUM 212°F (100°C)
ACID
RINSE
RINSE
RINSE
TILTED FLOOR
2 oz/gal (16 ml/l)
------
------
------
------
HW
HW
HW
PW
------
85%
------
85%
85%
------
RECIRCULATED
NON-RECIRCULATED
RECIRCULATED
NON-RECIRCULATED
------
02:00
00:35
01:00
00:35
01:00 (see note 1)
160°F (71°C) NON-GUARANTEED
------
185°F (85°C) NON-GUARANTEED
185°F (85°C)
MAXIMUM 212°F (100°C)
ACID
RINSE
RINSE
RINSE
FLOOR NOT TILTED
2 oz/gal (16 ml/l)
------
------
------
------
HW
HW
HW
PW
------
85%
------
85%
85%
------
------
------
------
------
------
------
------
------
------
60:00
------
------
------
------
MAXIMUM 212°F (100°C)
------
------
------
------
FLOOR NOT TILTED
------
------
------
------
------
------
------
------
------
------
------
------
------
------
------
RECIRCULATED
NON-RECIRCULATED
RECIRCULATED
NON-RECIRCULATED
------
02:00
00:35
01:00
00:35
01:00
160°F (71°C) NON-GUARANTEED
------
185°F (85°C) GUARANTEED
185°F (85°C)
MAXIMUM 212°F (100°C)
ACID
RINSE
RINSE
RINSE
FLOOR NOT TILTED
2 oz/gal (16 ml/l)
------
------
------
------
HW
HW
HW
PW
------
85%
------
85%
85%
------
LEGEND
HW
HOT WATER
PW
PURE WATER
GUARANTEED
TIMER ELAPSE ONLY WHEN ABOVE SET TEMPERATURE
NON-GUARANTEED
TIMER STARTS WHEN PUMP RUNS
SELECTED
NOT SELECTED
------
NOT APPLICABLE / NOT SELECTABLE
WASH 2 (OPTIONAL)
RINSE
FINAL RINSE
PURE WATER RINSE
DRYING (OPTIONAL) or
VAPOR EXHAUST
RECICULATED
NON-RECICULATED
RECICULATED
NON-RECICULATED
------
00:00 to 10:00
00:00 or 00:35
00:00 to 08:00
00:00 or 00:35
01:00 to 60:00 (see note 2)
120°F TO 165°F (49°C to 74°C) NON-
GUARANTEED
------
160°F TO 185°F (71°C to 85°C)
GUARANTEED or NON-
GUARANTEED
110°F TO 185°F (43°C to 85°C)
MAXIMUM 212°F (100°C)
ACID OR ALKALINE
RINSE
RINSE
RINSE
TILTED FLOOR OR NOT
0 to 4 oz/gal (0 to 32 ml/l)
------
------
------
------
HW
HW
HW
PW
------
0% TO 85%
------
0% or 85%
0% or 85%
------
Table 5-1. Cycle Description Chart – Basil 5700 LSR Cage and Rack Washer (Cont’d)