2-4
920512-768
Operator Manual
Installation Verification
❑
Verify for any construction and/or installation debris, inside and
outside wash chamber, under floor gratings and on sump filters.
Clean or discard.
❑
Verify spray headers and spray header cables. All cables are
properly tightened.
❑
Verify headers travel to the top and bottom of the wash chamber
without touching top or bottom pulleys and guides. Verify proper
installation.
❑
Inspect doors for alignment and smooth movement.
❑
Verify all the protective paper has been removed from stainless
steel.
❑
Floor underneath and surrounding unit has a noncombustible
and nonslip surface, or is covered with a metal sheet extending
to the outer edges of the unit.
❑
If Ramp Accessory is present,
ramp is correctly attached to
washer as specified in
S
ECTION
3
of
Uncrating/Installation
Instructions
(P920512-767).
IMPORTANT:
After a few weeks of operation, inspect unit for leaks.
Retighten all clamps and connections.