RoboClaw Series
Brushed DC Motor Controllers
RoboClaw Series User Manual
38
BASICMICRO
Battery Cut Off Settings
The RoboClaw is able to protect the main battery by utilizing a battery voltage cut off. The cut off
voltage will vary depending on the size of battery used. The table below shows the battery option
setting with the type of battery it will protect and at what voltage the cutoff will kick in. The
battery settings can be set by following the steps below.
1.
Press and release the LIPO button. The STAT2 LED will begin to blink out the current
setting.
2.
Press SET to increment to the next setting. Press MODE to decrement to the previous
setting.
3.
Once the desired setting is selected press and release the LIPO button to save this setting
to memory.
Battery Options
Option
Setting
Description
1
Disabled
6VDC is the default cut off when disabled.
2
Auto Detect
Battery must not be overcharged or undercharge! See Battery Settings.
3
3 Cell
9VDC is the cut off voltage.
4
4 Cell
12VDC is the cut off voltage.
5
5 Cell
15VDC is the cut off voltage.
6
6 Cell
18VDC is the cut off voltage.
7
7 Cell
21VDC is the cut off voltage.
8
8 Cell
24VDC is the cut off voltage.