Level the device. Use the level and appropriately
position the adjustable feet (fig. 2).
The height differences or tilting may negatively
influence the device operation.
Carefully remove the protective foil from the
external walls, avoiding leaving the glue
residuals.
Check if the ventilation holes and the vapours
outlet are not covered or blocked.
5.3 Water connection
The potable water connection must be positioned
in the vicinity of the device.
The water pressure must not be higher than 3 bar
(300 kPa). If the water pressure is higher, install
the pressure reducer before the device.
The water pressure should be in range
of 1.8 – 3 bar.
We recommend to install the water
softener/descaler in order to obtain the hardness
vale of 3 – 7° (German) (0.6 – 1.2 mmol/l).
For water hardness of 7° (German) and above
we recommend to connect the device with use
of appropriate water softener and the pressure
up to 3 bar.
The device is equipped with connection for the
delivered water supply hose. For the devices with
6 trays the connection is located in the bottom left
side (
fig. 3
), and for the devices with 10 trays – in
the bottom right side (
fig. 4
).