Safety precautions
4
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
2.5
Maintenance schedule
First of all, pay attention to the maintenance intervals prescribed by the body
manufacturer or measuring system installer for filters, hoses and liquids.
Daily:
CIP
Weekly:
Check service units for condensate residues and the contamination indi-
cator for signs of discolouration
Check pressure setting on service units
Change sampler hoses (At least every 10 days)
Check intake strainer
Monthly:
Check hydraulic oil cooler for excessive levels of impurity
Carry out vacuum test, if necessary, to check that measuring system is not
leaking
Biannually:
Check hydraulic oil level and top up if necessary
Check full alarm sensors
Carry out sampling process
Annually:
Check all screws to make sure that none are loose
Calibration
Check hydraulic oil and oil filter for impurities and change
Change milk hoses