Caution
Before starting pressure measurement, make
sure that there are no people around the
machine.
Lower the mower units, and then remove the
hydraulic hose from the adapter attached to
the hydraulic cylinder.
1
2
3
4
z4kw7w-009
Up/Down circuit_002
1
Mower unit
2
Cylinder
3
Adapter
4
Hydraulic hose
Install the pressure gauge for high pressure
measurements between the removed hose
and adapter.
1
2
3
z4kw7w-010
Up/Down circuit_003
1
Hydraulic hose
2
Adapter
3
Pressure gauge for high pressure
measurements
1.
2.
Make sure that the parking brake is applied,
and then start the engine.
1
z4kw7w-011
Up/Down circuit_004
1
Mower unit
Rev the engine up to the maximum rpm.
The normal pressure is 13.7 MPa (1,986.95
psi) when the up/down lever is shifted to the
"UP" position and the up/down cylinder is
retracted to its maximum.
Items to Prepare for Measurement
Prepare a pressure gauge for high pressure
measurements, T-joint TEF1/4, 6 adapter,
and 6 hydraulic hose.
10
20
30
15
25
35
5
1
2
4
2
3
2
z4kw7w-043
Up/Down circuit_005
1
6 Hydraulic hose
2
6 Adapter
3
Pressure gauge for high pressure
measurements
4
T-joint TEF1/4
3.
4.
5.
GM2810
Hydraulic system
Page 4-36
Measurement
Summary of Contents for GM2810
Page 1: ...5 Unit Rotary Mower Service Manual Serial No 10001 Ver 1 0...
Page 4: ...GM2810 Contents...
Page 10: ...GM2810 Safety Page 1 6 Safety Signs and Instruction Signs...
Page 11: ...Waste Disposal Page 2 2 About the Waste disposal Page 2 2 Disposal GM2810 Disposal Page 2 1...
Page 28: ...GM2810 Maintenance standards and maintenance Page 3 16 Greasing...
Page 82: ...GM2810 Hydraulic system Page 4 54 General inspection and repair...
Page 118: ...GM2810 Main body Page 6 4 Specifications...
Page 150: ...GM2810 Operating Machine and Mower Units Page 7 32 Inspection and repair of each section...
Page 164: ...GM2810 Troubleshooting Page 8 14 Relating to Operating Machine and Mower Unit...
Page 184: ...GM2810 Reference Page 9 20 RT mechanical brake manual...