Change of Brushes
Caution
During maintenance service, raise the empty
bucket.
Important
If the brush operation height is inadequate,
cores will not be properly collected.
Important
If the left and right sides of the brushes are at
different heights, the cores will not be
uniformly collected, and the brushes will wear
unevenly.
Important
Replace all brushes. Otherwise the weight will
become unbalanced and vibration may occur.
If the clearance between the rotary brush tips
and the brush frame cannot be adjusted to
approximately 5.0 mm (0.20 in) due to brush
wear, replace the brushes.
Move the machine to level ground.
Apply the parking brake.
Raise the bucket to its highest position.
Stop the engine.
Warning
To keep the position of raised bucket, be sure
to lock it with the cylinder lock.
Lock the bucket with the cylinder lock.
Remove the brush cover.
Remove the bolts securing the brush.
2
1
1
xsi3tb-005
Change of Brushes_001
1.
2.
3.
4.
5.
6.
7.
1
Bolt
2
Brush
Remove the rotary brush.
Install a new rotary brush.
Important
Evenly install the brush.
Adjust the brush so that there is a clearance
of approximately 5.0 mm (0.20 in) between
its tip and the brush frame, and then
temporarily tighten the bolts.
1
A
2
xsi3tb-006
Change of Brushes_002
1
Brush frame
2
Tip of rotary brush
A
5.0 mm (0.20 in)
Slowly rotate the rotary brushes by hand,
and then follow the same steps to adjust the
remaining brushes and temporarily tighten
the bolts.
Slowly rotate the rotary brushes by hand,
check the clearance again and tighten the
bolts so that all the clearances between the
brush tips and the brush frame will be the
same.
After making adjustments of all the brushes
and tightening the bolts, tighten all bolts
firmly.
Install the brush cover.
Start the engine, rotate the brushes, and
then check that there is no contact between
or vibration in the brushes and brush frame.
8.
9.
10.
11.
12.
13.
14.
15.
FS900
Maintenance
Page 6-12
Adjustment and Replacement