page 32
295 AC
800-00158
L90 STABILIZER VALVE BANK ADJUSTMENTS
NOTE: There is no pilot filter on this valve bank. Instead there is a remote filter.
To adjust the pressure, install a gauge on the load sense test port located on the tee on pump #1. Adjust the pressure
at the load sense adjustment screw on the load sense relief valve. Pressure should be 2500 PSI.
L90 STABILIZER VALVE BANK
Stab
Stab
Stab
Stab
Solenoids
(qty 8)
Remote Pilot
Oil Filter
Inlet
Cover
Outlet
Cover
Load Sense
Pressure Port
(PL)
B
A
B
A
B
A
B
A
B
A
Pilot Relief
(pressure reducing valve)
HYDRAULIC PRESSURE ADJUSTMENTS CONTINUED...
(FOR MODEL 295 AC)
Load Sense Pressure
Test Port
(on pump #1)
Pump #1
Pump #2
Load Sense
Relief Valve
Load Sense
Adjustment
Screw
Summary of Contents for 295