The rated current for sem
i
conductor fuses
i
s norma
ll
y g
i
ven by the fuse manufacturers for copper conductors
that have a current dens
i
ty
i
n the order of 1.3 - 1.6 A/mm (IE C 2 6 9-4). Th
i
s
l
o w ut
ili
sat
i
on resu
l
ts
i
n extra
copper costs dur
i
ng the
i
nsta
ll
at
i
on of h
i
gh current systems, but he
l
ps to prevent overheat
i
ng of the fuses.
A
l
ternat
i
ve
l
y
i
t
i
s poss
i
b
l
e to use a fuse of a h
i
gher rat
i
ng, and derate
i
t for use
i
n standard fuseho
l
ders and
i
nsta
ll
at
i
ons. Th
i
s derat
i
ng factor
i
s on
l
y app
li
ed to
l
arge fuses for the mode
l
s PL/X 1 8 5/2 2 5/2 6 5. Hence the
fuses
i
n the tab
l
e for these mode
l
s have been se
l
ected w
i
th a further derat
i
ng to approx. 8 0 %
i
n order that
they may be used
i
n a standard fuseho
l
der. No derat
i
ng
i
s requ
i
red for
i
nsta
ll
at
i
ons that do comp
l
y w
i
th IEC
2 6 9-4, and
i
n th
i
s case a sma
ll
er fuse cou
l
d be se
l
ected
i
n accordance w
i
th the recommendat
i
ons g
i
ven
above.
1 4.3.1 Propr
i
etary fuses
LIT TLEFUSE
BUSS
BUSS EU
IR A mer
i
can
sty
l
e
IR BS8 8
IR DIN
Max cont
Current
(A MPS)
Mode
l
PL 2 Q
PLX 4 Q
IP
A C
OP
D C
Ma
i
n
fuses
max
I
2
t
Up to
2 5 0 V ac
supp
l
y
Up to
5 0 0 V ac
supp
l
y
Up to
5 0 0 V ac
supp
l
y
Up to
5 0 0 V ac
supp
l
y
Up to 5 0 0 V
ac supp
l
y
Up to
2 5 0 V ac
supp
l
y
Up to 5 0 0 V
ac supp
l
y
PL/X 5
1 0
1 2
6 0 0
L2 5S 1 2
L5 0S 1 2
F W H 1 2
F W H 2 0 A 1 4F
XL5 0 F 0 1 5
L3 5 0-1 2
6 6 1RF 0 0 2 5
PL/X 1 0
2 0
2 4
6 0 0
L2 5S 2 5
L5 0S 2 5
F W H 2 5
1 7 0L1 0 1 3
XL5 0 F 0 2 5
L3 5 0-2 5
6 6 1RF 0 0 2 5
PL/X 1 5
3 0
3 6
6 0 0
L2 5S 4 0
L5 0S 4 0
F W H 4 0
1 7 0L1 0 1 3
XL5 0 F 0 4 0
L3 5 0-4 0
6 6 1RF 0 0 3 5
PL/X 2 0
4 0
5 1
5 0 0 0
L2 5S 5 0
L5 0S 5 0
F W H 5 0
1 7 0 M 1 5 6 4
XL5 0 F 0 5 0
L3 5 0-5 0
6 6 1RF 0 0 5 0
PL/X 3 0
6 0
7 2
5 0 0 0
L2 5S 8 0
L5 0S 8 0
F W H 8 0
1 7 0 M 1 5 6 6
XL5 0 F 0 8 0
L3 5 0-8 0
6 6 1RF 0 0 8 0
PL/X 4 0
8 0
9 9
5 0 0 0
L2 5S 1 0 0
L5 0S 1 0 0
F W H 1 0 0
1 7 0 M 1 5 6 7
XL5 0 F 1 0 0
L3 5 0-1 0 0
6 6 1RF 0 0 1 0 0
PL/X 5 0
1 0 0
1 2 3
1 1 8 5 0
L2 5S 1 2 5
L5 0S 1 2 5
F W H 1 2 5
1 7 0 M 1 5 6 8
XL5 0 F 1 2 5
L3 5 0-1 2 5
6 6 1RF 0 0 1 2 5
PL/X 6 5
1 2 4
1 5 5
6 0 0 0 0
L2 5S 1 7 5
L5 0S 1 7 5
F W H 1 7 5
1 7 0 M 1 5 6 9
XL5 0 F 1 7 5
L3 5 0-1 8 0
6 6 1RF 0 0 1 6 0
PL/X 8 5
1 6 4
2 0 5
6 0 0 0 0
L2 5S 2 2 5
L5 0S 2 2 5
F W H 2 5 0
1 7 0 M 3 8 1 6
XL5 0 F 2 5 0
T 3 5 0-2 5 0
6 6 1RF 0 0 2 5 0
PL/X 1 1 5
2 1 6
2 7 0
1 2 8 0 0 0
L2 5S 2 7 5
L5 0S 2 7 5
F W H 3 0 0
1 7 0 M 3 8 1 6
XL5 0 F 3 0 0
T 3 5 0-3 1 5
6 6 1RF 0 0 3 1 5
PL/X 1 4 5
2 7 0
3 3 0
1 2 8 0 0 0
L2 5S 3 5 0
L5 0S 3 5 0
F W H 3 5 0
1 7 0 M 3 8 1 8
XL5 0 F 3 5 0
T 3 5 0-3 5 5
6 6 1RF 0 0 3 5 0
PL/X 1 8 5
3 5 0
4 3 0
2 4 0 0 0 0
L2 5S 4 5 0
L5 0S 4 5 0
F W H 4 5 0
1 7 0 M 5 8 0 9
XL5 0 F 4 5 0
T T 3 5 0
-5 0 0
6 6 1RF 0 0 4 5 0
PL/X 2 2 5
4 3 5
5 3 0
2 4 0 0 0 0
No fuse
ava
il
ab
l
e
L5 0S 5 5 0
F W H 6 0 0
1 7 0 M 5 8 1 1
XL5 0 F 6 0 0
T T 3 5 0
-6 3 0
6 6 1RF 2 6 3 0
PL 2 6 5
5 2 0
6 3 0
3 0 6 0 0 0
No fuse
ava
il
ab
l
e
No fuse
ava
il
ab
l
e
F W H 7 0 0
1 7 0 M 5 8 1 1
XL5 0 F 7 0 0
T T 3 5 0
-7 1 0
6 6 1RF 2 7 0 0
P
l
ea
s
e
a
l
so
r
e
f
e
r
to
Pa
r
t 3
PL
/X 275-980 fo
r
e
xt
r
a
d
e
t
a
il
s of f
r
a
m
e
4
a
nd 5 h
i
gh pow
e
r
d
ri
v
e
s.
1 4.3.2 European stock fuses
ST O C K part number
Mode
l
PL 2 Q
PLX 4 Q
Max
IP A C
A mps
Ma
i
n
fuses
max
I
2
t
M AIN FUSE
3 fuses
requ
i
red
M AIN FUSE S
i
ng
l
e
po
l
e ho
l
der
3 requ
i
red
A U X FUSE
3 fuses
requ
i
red
A U X FUSE
S
i
ng
l
e po
l
e
ho
l
der
3 requ
i
red
PL/X 5
1 0
6 0 0
C H 0 0 6 1 2 A
CP1 0 2 0 7 1
1 4 X 5 1
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 1 0
2 0
6 0 0
C H 0 0 7 4 0 A
CP1 0 2 0 5 3
1 4 X 5 1
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 1 5
3 0
6 0 0
C H 0 0 7 4 0 A
CP1 0 2 0 5 3
1 4 X 5 1
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 2 0
4 0
5 0 0 0
C H 0 0 8 5 0 A
CP1 0 2 0 5 4
S
i
ze 0 0
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 3 0
6 0
5 0 0 0
C H 0 0 8 8 0 A
CP1 0 2 0 5 4
S
i
ze 0 0
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 4 0
8 0
5 0 0 0
C H 0 0 8 1 0 0
CP1 0 2 0 5 4
S
i
ze 0 0
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 5 0
1 0 0
1 1 8 5 0
C H 0 0 8 1 2 5
CP1 0 2 0 5 4
S
i
ze 0 0
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 6 5
1 2 4
6 0 0 0 0
C H 0 0 8 1 6 0
CP1 0 2 0 5 4
S
i
ze 0 0
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 8 5
1 6 4
6 0 0 0 0
C H 0 0 9 2 5 0
CP1 0 2 0 5 5
S
i
ze 1
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 1 1 5
2 1 6
1 2 8 0 0 0
C H 0 0 9 2 5 0
CP1 0 2 0 5 5
S
i
ze 1
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 1 4 5
2 7 0
1 2 8 0 0 0
C H 0 1 0 5 5 0
CP1 0 2 2 3 3
S
i
ze 3
C H 0 0 6 2 0 A
CP1 0 2 0 7 1
PL/X 1 8 5
3 5 0
2 4 0 0 0 0
C H 0 1 0 5 5 0
CP1 0 2 2 3 3
S
i
ze 3
C H 0 0 8 5 0 A
CP1 0 2 0 5 4
PL/X 2 2 5
4 3 5
2 4 0 0 0 0
C H 0 1 0 5 5 0
CP1 0 2 2 3 3
S
i
ze 3
C H 0 0 8 5 0 A
CP1 0 2 0 5 4
PL 2 6 5
5 2 0
3 0 6 0 0 0
C H 0 1 0 7 0 0
CP1 0 2 2 3 3
S
i
ze 3
C H 0 0 8 5 0 A
CP1 0 2 0 5 4
P
l
ea
s
e
a
l
so
r
e
f
e
r
to
Pa
r
t 3
PL
/X 275-980 fo
r
e
xt
r
a
d
e
t
a
il
s of f
r
a
m
e
4
a
nd 5 h
i
gh pow
e
r
d
ri
v
e
s..
Summary of Contents for PLX