Required tools
•
Flat screw driver 4 x 100 mm
•
Torque wrench with flat-head socket (medium size)
Required parts
Certified AC power supply cord, min. 500V. Take into account that the cable gland of the projector allows a
cable diameter from 11 to 21 mm.
How to connect the projector with the mains electricity?
1.
Remove the cover of the mains compartment. See procedure
“
Accessing the mains compartment
”
, page 51.
2.
Push the stripped AC power supply cord through the cable gland (reference 2 Image 6-17).
3.
Connect the wires to the 5-terminal strip (reference 1 Image 6-17) as illustrated. Use a torque screw driver to
fasten the screws of the 5-terminal strip with a torque of
1.7Nm
(1.25 lbf*ft).
Always connect the ground wire (PE) with the connector indicated with PE on the terminal barrier strip.
If a neutral conductor is available, connect always to the connector indicated with N on the terminal barrier
strip.
Warning:
Connect first the PE wire, then the other wires.
Caution:
When using a flexible AC power supply cord, make sure that each conductor end is provided
with an end sleeve.
Tip:
Check for good fixation by pulling on each wire.
L1
L1
L1
L1
L2
L2
L2
L2
L3
L3
L3
N
N
PE
PE
PE
PE
PE
2
1
Image 6-17
4.
Secure the AC power supply cord by fastening the cable gland (reference 2 Image 6-17).
5.
Install the cover of the mains compartment.
6.9 Power loop through to the projector electronics
This procedure explains how to provide the projector electronics with power in case no UPS unit is
used. Note that the projector is by default configured for use without UPS. So, the short power link
cable is already installed.
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...