R5906788-03
Thor series
51
CAUTION:
Do not interchange the different cooling circuits with each other! Otherwise the system
will fail.
CAUTION:
The minimum bend radius of the hoses is 30 centimeter.
6.4 Connecting the data cable with projector and
chillers
What has to be done?
Next to connecting the hoses, the communication port of the chillers has to be connected with each other and
with the projector.
Depending on the projector model one or two chillers are required! For the Thor series projector one chiller
has to be installed. The Thor+ series needs two chillers.
Required parts
•
One long (10 meter) communication cable with SUBD Male/Female 15 pins plugs.
•
One short (5 meter) communication cable with SUBD Male/Female 15 pins plugs (only if two chillers are
required).
How to connect the communication ports of the chillers with the projector?
1.
Does the system contain two chillers?
►
If yes,
connect the output port of one chiller (reference 1 Image 6-9) with the input port of the other chiller
(reference 2 Image 6-9). Use for this a short communication cable.
►
If no,
proceed with the next step.
2.
Connect the output port of the chiller (reference 3 Image 6-9) with the communication port of the projector
(reference 4 Image 6-9). Use for this a long communication cable.
Tip:
Guide the long communication cable together with the hoses.
2
4
3
1
Image 6-9
6.5 Accessing the mains compartment
Required tools
•
Phillips screwdriver PH1
•
Allen wrench 3 mm
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...