R5906788-03
Thor series
32
Image 3-10
Flexible Touch Panel interface
The Touch Panel interface can be mounted upon a swivel arm which easily fits on top of the Thor series. One
central locking mechanism of the swivel arm allows instant fixation of the Touch Panel interface in any
position.
The Touch Panel interface can also be installed further away from the Thor series. For this purpose an
Ethernet cable up to 50 meter can be used to realize a direct data communication between the Thor series
and the Communicator Touch Panel.
The Touch Panel interface can also be connected via a Local Area Network (LAN) in the same way as the
Thor series. In this configuration both devices can communicate with each other as well.
The Touch Panel interface requires a voltage 12 VDC and 1,5 ampere. Note that the Thor series has
a 12 VDC output which can be used to power up the Touch Panel interface. Nevertheless, the use of a
se12 VDC adaptor (1,5 ampere minimum) is required in case the Touch Panel interface is installed
more then a few meters away from the Thor series.
Parts location of the Touch Panel interface
1
2
3
4
5
6
7
Image 3-11
1
Touch screen
2
Communication panel
3
Knob to operate central swivel clamp
4
Base of swivel arm
5
Power input 12 VDC, 1.5A
6
RS232 port (sub-D)
7
Ethernet port (RJ45)
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...