75
R5914712 /00
SP2K-C
7.3 What are the possible HDD swaps
General
There are several possible scenarios for replacing (exchange) hard drives on the ICMP-X. The situation is
different depending on the device type (ICMP or ICMP-X) and whether to replace one or more disks.
Continuity of data present on the disks is also impacted depending on the type of exchange. Degraded
operation or RAID initialization may be required.
List of available actions
The following table exposes all possible swaps available concerning HDDs on ICMP-X:
Replacing drives should always be done while the power is off.
Type of HDD swap
On ICMP
On ICMP-X
1 HDD replaced.
•
Content is preserved.
•
ICMP automatically starts rebuild.
•
Process takes about 3-4 hours
for 1TB HDD and could takes
about 13-14 hours for 4TB HDD.
•
Content is preserved.
•
ICMP-X automatically starts
rebuild.
•
Process takes about 3-4 hours
for 1TB HDD and could takes
about 13-14 hours for 4TB HDD.
3 HDDs replaced separately
(previous kit of one disk used
three times).
•
All content will be lost.
•
RAID initialization need to be
perform with Communicator.
•
immediately usable after RAID
initiali restart (content
can be ingested).
•
All content will be lost.
•
RAID initialization need to be
perform with Web Communicator.
•
immediately usable after RAID
initiali restart (content
can be ingested).
Barco HDD replacement kit
without S4 ready sticker
(Spare part kit provided by
Barco with a set of 3 hard
disks configured to GEN1
storage controller).
On an ICMP with GEN1 storage
Controller:
•
RAID initialization does not need
to be performed.
•
Content can be ingested
immediately.
On an ICMP with GEN2 storage
Controller:
•
Only usable after RAID
initiali restart.
•
Content can be ingested
immediately after restart.
•
RAID initialization needs to be
perform with Web Communicator.
•
immediately usable after RAID
initiali restart (content
can be ingested).
Barco HDD replacement kit
with S4 ready sticker
(New
Spare part kit provided by
Barco with a set of 3 hard
disks configured to GEN2
storage controller).
On an ICMP with GEN1 storage
Controller:
•
Only usable after RAID
initialization with Commun
restart (content can then be
ingested immediately).
On an ICMP with GEN2 storage
Controller:
•
RAID initialization does not need
to be performed.
•
Content can be ingested
immediately after restart.
•
RAID initialization does not need
to be performed.
•
Content can be ingested
immediately.
Summary of Contents for SP2K-C
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual SP2K C...
Page 4: ......
Page 8: ...R5914712 00 SP2K C 8...
Page 48: ...R5914712 00 SP2K C 48 Physical installation projector...
Page 62: ...R5914712 00 SP2K C 62 Lenses Lens holder...
Page 70: ...R5914712 00 SP2K C 70 ICMP X...
Page 90: ...R5914712 00 SP2K C 90 ICMP X...
Page 98: ...R5914712 00 SP2K C 98 Projector Power Cycle...
Page 104: ...R5914712 00 SP2K C 104 Connectivity...
Page 107: ...107 R5914712 00 SP2K C Image 10 3 Sealed top cover remove Convergence...
Page 109: ...109 R5914712 00 SP2K C 1 1 Image 10 6 Sealed cover fixation Convergence...
Page 116: ...R5914712 00 SP2K C 116 Convergence...
Page 132: ...R5914712 00 SP2K C 132 Image 12 13 Tightening the screws of the side cover Projector covers...
Page 140: ...R5914712 00 SP2K C 140 Dimensions...
Page 146: ...R5914712 00 SP2K C 146 Restriction Zone clarification and use cases...
Page 150: ...R5914712 00 SP2K C 150 List of tools...
Page 154: ...R5914712 00 SP2K C 154 Index...
Page 155: ......