![background image](http://html1.mh-extra.com/html/barco/rhdm-2301/rhdm-2301_user-manual_3809077147.webp)
Barco - RHDM-2301 - User manual ___________________________________________________ 147
Addendum
Error
code
Warning/
Fault
Name
Description
0
Display status
When a fault or warning occurs for one of the nodes listed
below, the error code “0” is generated.
1
Calibration
Node related to calibration warnings due to operation of
the display unit
101
W
Background
Background of window 1 is set to a value out of the cali-
brated range
102
W
Gain
The gain of window 1 is set to a value out of the calibrat-
ed range
103
W
Saturation
The saturation of window 1 is set to a value out of the cal-
ibrated range
104
W
Hue
The hue of window 1 is set to a value out of the calibrated
range
105
W
RGB channels
Not all color channels (R,G,B) are used for the output on
the screen for window 1
106
W
Monochrome
The output to the screen is set to monochrome for win-
dow 1
151
W
Background
Background of window 2 is set to a value out of the cali-
brated range
152
W
Gain
The gain of window 2 is set to a value out of the calibrat-
ed range
153
W
Saturation
The saturation of window 2 is set to a value out of the cal-
ibrated range
154
W
Hue
The hue of window 2 is set to a value out of the calibrated
range
155
W
RGB channels
Not all color channels (R,G,B) are used for the output on
the screen for window 2
156
W
Monochrome
The output to the screen is set to monochrome for win-
dow 2
2
Licensing
Node related to Faults and warnings related to the licens-
ing. More details can be found in the maintenance man-
ual.
3
Spectrometer
Node related to spectrometer faults
301
F
Spectrometer sta-
tus: Error
Hardware fault
302
F
No spectrometer
found
Hardware fault