![background image](http://html1.mh-extra.com/html/barco/rhdm-2301/rhdm-2301_user-manual_3809077122.webp)
122 ____________________________________________________Barco - RHDM-2301 - User manual
Addendum
7.1.3.4.2
EN norms
• The unit is targeted to meet following EN specifications:
• EN55024 – Susceptibility specifications
7.1.3.4.3
FCC norms
• Unit meets FCC part 15 level A
Reference
Test Description
Performance Level
Compliant
EN 55022
Conducted Emission
A
YES
EN 55022
Radiated Emission
A
YES
EN 61000-3-2
Conducted Emission Har-
monic Currents
According to Class D
YES
EN 61000-3-3
Voltage Changes Fluctua-
tion
Not applicable
YES
Reference
Test Description
Performance Level
Compliant
EN 61000-4-2 ESD
ESD
4kV contact
8 kV air
Level 3
YES
EN 61000-4-3
Electro Magnetic Field
3 V/m
Level 2
YES
EN 61000-4-4
Burst
0.5 kV Signal ports if ca-
ble > 3m
1 kV on lines & earth
Level 3
YES
EN 61000-4-5
Surges
1.5 kV Signal ports if out-
door
1 kV line to line
2 kV line to earth
Level 3
YES
EN 61000-4-6
Conducted Common Mode 3 V
level 2
YES
EN 61000-4-8
Power Frequency Magnetic
Field
Not Applicable
YES
EN 61000-4-11
Voltage Dips
Dip 95% for 0,5 period
Dip 30% for 25 periods
Interrupt: 95% for 250
periods
Cannot be compared to
generic test level
YES