Service Mode
10-4
5975618A RETRO BLOCK GRAPHICS 2100LC 240898
Change Baud Rate PC
The communication speed between projector and computer, e.g. PC
or MAC, has 8 possible speeds. The baud rate speed can be
software set up.
Highlight 'Change Baud rate PC' by pushing the control disk up or down
and press
ENTER
to display the 'Change Baud Rate PC' menu.
The following baud rates are available :
- 9600
- 4800
- 2400
- 1200
- 600
- 300
- 150
- 75
The actual baud rate will be highlighted. To change the baud rate,
push the control disk up or down and press
ENTER
to accept the new
baud rate setting.
Reset Lamp Runtime
Reset lamp run time is only allowed when a new lamp is installed.
Highlight Reset Lamp Run Time by pushing the control disc up or down
and press
ENTER
to select.
When Reset Lamp Run Time is selected in the Service Mode selection
menu, the following warning will be displayed :
"Risk of electrical shock. Reset lamp run time is reserved to qualified
service personnel."
If you are not qualified, press
EXIT
to cancel the reset operation.
Lamp Run Time History
To get an overview of the different lamp run times, highlight Lamp Run
Time History by pushing the control disc up or down and press
ENTER
.
A listing with the lamp serial number and the corresponding run time
will be displayed.
The actual installed lamp will be marked.
Press
ENTER
to have more details.
Press
EXIT
to return to the service mode selection menu.
CHANGE BAUDRATE PC
9600
4800
2400
1200
600
300
150
75
Select with
ê
or
é
<ENTER> to accept
<EXIT> to return.
WARNING
-----------------------------------------------------
RISK OF
ELECTRICAL SHOCK
______________________________________________________________
RESET LAMP RUN TIME
is reserved to
qualified
service personnel
<ENTER> to continue
<EXIT> to return.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTIME HISTORY
LAMP RUNTIME HISTORY
Serial No
Runtime
-----------------------------------------------------
>
0111121
600 h
0110031
980 h
0110010
1000 h
<ENTER> for detail
<EXIT> to return
LAMP RUNTIME HISTORY
Serial Number:
1234567
Article Number:
R9829510
Remaining lamp run time:
990 hours
<EXIT> to return
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTINE HISTORY
LAMP DRIVE MODE
MORE...
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
CHANGE BAUDRATE PC
RESET LAMP RUNTIME
LAMP RUNTIME HISTORY
LAMP DRIVE MODE
MORE...