6. Final Adjustment and Configuration
Barco – OverView cDG67-DL – R5976624– installation manual – Revision 03 – August-2005
______________________________________________________________
6-24
To change the values
•
Increase
4
or decrease
3
the value by means of the arrow keys.
The menus vanish by pressing Exit on the IR Remote-Control unit or if there is no change
within 5 seconds.
Please note:
These settings are only valid for the optical dimmer b eing disab led. In case the optical
dimmer is enabled again, these settings are set back to their neutral positions (50)!
6.6.4.6
DIS Calibration Factor
The DIS Calibration Factor is determined by CAST.
Only experienced user equiped with a lux meter should change the value!
All
DIS
values that are displayed and used in the projector are composed by the raw data of the
DIS
multiplied by
a calibration factor.
ta
DIS raw da
n factor)*
-correctio
or *(
ratin Fact
DIS Calib
DIS value
1
=
This calibration factor can be set by means of the menu
Service | Color/Brightness | DIS calibration factor.
To
change the calibration factor:
•
Use the cursor key to highlight
DIS Calibration Factor
.
•
Press
Enter
to select.
The current
DIS Calibration Factor
is displayed.
Figure 6-33
DIS calibration factor
The DIS Calibration Factor can only be changed for the active lamp!
The DIS Calibration Factor can be changed between 1.000 and 9.999
The DIS Calibration Factor is set for both lamps individually.