7. Manual User Interface
Barco – OverView cDG67-DL – R5976624– installation manual – Revision 03 – August-2005
________________________________________________________________
7-2
7.2
Standby Switch
The Standby Switch [B] has 3 positions: neutral (not pushed), up (pushed to the top), down (pushed to the
bottom).
The switch is slope sensitive and reacts when changing from one position to the other. To prevent operation
errors, a minimum time is required for pushing. After sending a command (after pushing the switch), the next
command can only be sent after the release of the switch for at lease 0.5s.
In case the power switch [A] is off, there is no reaction.
Projector status
Power LED
Action Push
time
Function
Up
switching on the projector
Standby
(no error)
red, static
Down
only in combination with active lamp selection switch
[3], for servicing only
Up
3sec
reset of error after servicing
Standby
(error)
red,
blinking fast
Down
no function
Up
only in combination with active lamp selection switch
[3]
On
(no error)
green, static
Down 3sec
switching off the projector (standby)
Up
6sec
reset of non critical error
On
(error)
green,
blinking slowly
down 3sec
switching off the projector (standby),
reset of non critical error
Up
no function
Projector is
starting up or
shutting down
blinking yellow
Down
no function