3. Mechanical setup
Barco – OverView cDG67-DL – R5976624– installation manual – Revision 03 – August-2005
________________________________________________________________
3-5
3.3
Assembling the structure
ASM01
When assembling PA05 (left and right) start
with PA04 to make the first cross-connection.
When this connection has been made it’s
easier to assemble the r840380-profiles
ASM02
When step 01 is finished and the first unit of
the wall is positioned in place then start
mounting the first connection brackets. The
bracket is aligned to the corner bracket. The
type of bracket is defined by the curvature
definition of the wall (see figure above).
Connection-brackets for 0°, 3°, 5° and 8° are
standard; other angles are possible when
customized. Notice that you then level the
structure!
Make sure to use nippled hammer bolts to
Make sure to use nippled hammer bolts to
Make sure to use nippled hammer bolts to
Make sure to use nippled hammer bolts to
fix the connection brackets!
fix the connection brackets!
fix the connection brackets!
fix the connection brackets!