![background image](http://html.mh-extra.com/html/barco/nsl-4601/nsl-4601_user-manual_473759088.webp)
RS232 Protocol NSL-4601
36 of 58
3.3 COLOR
3.3.1 COLOR
TEMPERATURE(USER-COOL2-COOL1-NORMAL-WARM2-WARM1,
Default = COOL2)
Send to monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
CT0
.
Reply to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) CRT=
1
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
Send Cmd
(char-3Bytes)
MODE
Reply
(CRT=*)
CT0 USER 0
CT1 COOL1 1
CT2 COOL2 2
CT3 NORMAL 3
CT4 WARM1 4
CT5 WARM2 5
3.3.2 BRIGHTNESS(Range
0~100, Default value = 50)
-
Up
Send to Monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
BRU
.
Reply to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) BRU=
2
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
-
Down
Send to Monitor