RS232 Protocol NSL-4601
21 of 58
25
CPS
Current Power status
26 MLT
MHC,MVC,MHG,MVG,DNO
27 COL BRT,CON,TIN,SAT,SHA,CRT,BLT,S
BR,ROF,GOF,BOF,SCO,RGN,GGN,B
GN
28 PIC
PIM,PIS,HPS,VPS,CLK,PHS
29 ETC
CPS,CSR,AGI.KLC
30
RGD Read
Gamma
Data
Example2: Get Menu Group setting status
In order to query the Multi set menu group setting status the following PU is send to the device:
Head
(char-2Bytes)
ID
(char-3Bytes)
Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
MLT
?
This answer is retuned from the device. It indicates that the request did succeed and the current
Set Id, HMaxCell, VMaxCell, H Gap, V Gap, Cell No and Ack/Nack is returned.
ID
(char-3~5Bytes)
(0)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
MHC= 2
\r\n
MVC= 2
MHG= 1
MVG= 1
DNO= 2
ACK
(Hexa-1Byte)
0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
In order to query the Color set menu group setting status the following PU is send to the device:
Head
(char-2Bytes)
ID
(char-3Bytes)
Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
COL
?
This answer is returned from the device. It indicates that the request did succeed and the current
Set Id, Brightness, Contrast, Hue(Tint), Saturation(Color), Sharpness, Coor