RS232 Protocol NSL-4601
26 of 58
3 Command
Reference
The command reference lists all commands, with a short explanation of their effect and details
about the command request protocol unit and the command reply protocol unit. The command
reference is organized.
3.1 Operation
Modes
3.1.1
Read (only ONE SET selected)
-
Multi Control Menu(
in case
HMaxCell=2, VMaxCell=2, H Gap=1, H Gap=0, Cell No=2
)
Send command to Monitor(current Brightness is 54(0x36))
Head
(char-2Bytes)
ID
(char-3Bytes)
Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
MLT
?
Reply to PC
ID
(char-3~5Bytes)
(0)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
MHC= 2
\r\n
MVC= 2
MHG= 1
MVG= 1
DNO= 2
ACK
(Hexa-1Byte)
0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
-
Color Control Menu
Head
(char-2Bytes)
ID
(char-3Bytes)
Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
COL
?
Reply to PC
ID
(char-3~5Bytes)
(0)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
BRT= 50
\r\n