RS232 Protocol NSL-4601
35 of 58
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Data
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
DNO
001 .
Reply Monitor to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) DNO
=
1
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
Send PC to Monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Data
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
MHG
002 .
Reply Monitor to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) MHG=
2
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
Send PC to Monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Data
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
MVG
002 .
Reply Monitor to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) MVG=
2
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
3.2.7
Read Multi setting status(only for single monitor)
This function is for updating current multi setting status of selected one monitor. This is not
available in all set or group selected.
See 3.1.1 Read (only ONE SET selected)