RS232 Protocol NSL-4601
33 of 58
(char-2Bytes)
(char-3Bytes)
(char-3Bytes)
(char-3Bytes)
(char-1Byte)
K: 000
MHC
002 .
Reply to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) MHC=
2
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
-
Get current H Max Cell setting status
See Read Multi setting status
.
3.2.2
Multi Window Adjust V Max cell(Range 1~16, Default value = 1)
Same format as Multi Window Adjust H Max cell
but send cmd is “MVU”, “MVD”, “MVC” and return cmd is “MVC=”.
3.2.3
Multi Window Adjust Cell Number(Range 1~ H Max cell x V Max cell, Default
value = 1)
Same format as Multi Window Adjust H Max cell
but send cmd is “DNU”, “DND”, “DNO” and return cmd is “DNO=” .
3.2.4
Multi Window Adjust H Gap(Range 0~20, Default value = 0)
Same format as Multi Window Adjust H Gap
but send cmd is “HEU”, “HED”, “MHG” and return cmd is “MHG =”.
3.2.5
Multi Window Adjust V Gap(Range 0~20, Default value = 0)
Same format as Multi Window Adjust H Gap
but send cmd is “VEU”, “VED”, “MVG” and return cmd is “MVG =”.
3.2.6
Multi Window Adjust Apply
This function is for setting all multi set items(H Max Cell, V Max Cell, Cell No, H Gap, V Gap) at
once.
1) All Set Control
Send PC to Monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Data
(char-3Bytes)
Cmd end
(char-1Byte)
K: ALL
MHC
002 .
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Data
(char-3Bytes)
Cmd end
(char-1Byte)
K: ALL
MVC