RS232 Protocol NSL-4601
45 of 58
0 Off
1 On
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
3.5.2
Read IR/KEY setting status(only for single monitor)
This function is for updating current factory mode setting status of selected one monitor. This is not
available in all set or group selected.
See 3.1.1 Read (only ONE SET selected)
3.6 ETC
3.6.1
AGING MODE(OFF- FULL WHITE - FULL RED - FULL GREEN – FULL BLUE,
Default = OFF)
Send to monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
AG1
.
Reply to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data
(char-1~3Bytes)
Data End
(char-2Bytes “\r\n”)
ACK
(Hexa-1Byte)
(0) AG1=
1
\r\n 0x06
or
ID
(char-3~5Bytes)
NACK
(Hexa-1Byte)
(0) 0x15
3.6.2 KEY
LOCK(On/Off, Default = Off)
This function is for locking or unlocking OSD key. OSD menu key, source key, .select key, up key,
down key, left key and right key don’t work in Key Lock on status. But OSD power key and IR
control isn’t locked in Key Lock On status.
Send to monitor
Head
(char-2Bytes)
ID
(char-3Bytes)
Send Cmd
(char-3Bytes)
Cmd end
(char-1Byte)
K: 000
KLN
.
Send Cmd
(char-3Bytes)
Key Lock
KLN On