189
R5910032 /00
Freya
1
2
Image 9
–
3 White Point Calibration
–
White Point Tracking
The laser white point calibration will be reset. The default settings are programmed.
2.
Click
Next
(reference 2) to access the 2D measurement.
3
4
Image 9
–
4 White Point calibration - 2D measurement
3.
Measure the white coordinates (x, y) with spectrometer and enter in the x and y fields respectively
(reference 3).
4.
If 3D projection is required, click
Next
(reference 4) to access the 3D measurement. If not, press
cancel
to
exit.