17. Troubleshooting
Optional indicator
Optional indicator
Value
Comments
High
01h
Low
00h
Type
Type
Description
Note / Recommendation
INFO
Messages of this type informs the user about an event or
status change.
WARN-
ING
Messages of this type warns the user that system
performance will be impacted and/or stability/safety could
be compromised if no corrective action is taken.
An action by the user to resolve the issue is advised.
ERROR
Messages of this type alerts the user that system
performance or image quality (including no image) is visibly
impacted and/or stability/safety is compromised.
An immediate action by the user is required.
Only error and warning messages are enumerated in the troubleshooting list below.
17.4.2 Troubleshooting checklist
Code E0000000: “Environment temperature too low” (Error)
Situation
Solution
Ambient temperature too low.
Make sure the projector operates within specs and make sure that the installation
requirements are ful
fi
lled.
Code E0000001: “Environment temperature exceeded” (Error)
Situation
Solution
Ambient temperature too high.
•
Check the ambient temperature at the front air inlets of the projector.
•
Check air
fl
ow of the projector.
•
Make sure the projector operates within specs and make sure that the installation
requirements are ful
fi
lled.
Code E0000101: “Mainboard sensor temperature exceeded” (Error)
Situation
Solution
Main board is not suf
fi
ciently cooled.
•
Check environmental conditions.
•
Check whether fans on main board are running as expected.
Code E0000201: “Mainboard IMX temperature exceeded” (Error)
For this error the same troubleshooting table can be applied to as for code
E0000101
: “Mainboard sensor temperature exceeded”.
Code E0000301: “Mainboard FPGA temperature exceeded” (Error)
For this error the same troubleshooting table can be applied to as for code
E0000101
: “Mainboard sensor temperature exceeded”.
Code E0000401: “Mainboard Scaler FPGA temperature exceeded” (Error)
For this error the same troubleshooting table can be applied to as for code
E0000101
: “Mainboard sensor temperature exceeded”.
Code E0000500: “Barometric pressure lower limit reached” (Error)
Situation
Solution
Environmental pressure not within
range as normally supported by the
projector.
Ensure that environmental conditions comply with the operation requirements of the
projector. See installation manual of the projector for detailed installation requirements.
68
723–0016 F90 01/12/2017
Summary of Contents for F90 series
Page 1: ...F90 Service Manual 723 0016 02 01 12 2017...
Page 6: ...Table of contents 4 723 0016 F90 01 12 2017...
Page 8: ...1 Introduction 6 723 0016 F90 01 12 2017...
Page 10: ...2 General safety 8 723 0016 F90 01 12 2017...
Page 18: ...4 DLP System General Description 16 723 0016 F90 01 12 2017...
Page 25: ...5 GP6 system functional description Image 5 5 723 0016 F90 01 12 2017 23...
Page 28: ...5 GP6 system functional description 26 723 0016 F90 01 12 2017...
Page 34: ...7 OSD display menu 32 723 0016 F90 01 12 2017...
Page 36: ...8 Thermal management system Image 8 1 34 723 0016 F90 01 12 2017...
Page 42: ...8 Thermal management system 40 723 0016 F90 01 12 2017...
Page 58: ...14 XPS actuator 56 723 0016 F90 01 12 2017...
Page 60: ...15 Light engine 58 723 0016 F90 01 12 2017...
Page 82: ...18 Assembly Hierarchy 80 723 0016 F90 01 12 2017...
Page 103: ...20 Scheduled operations Image 20 42 Image 20 43 723 0016 F90 01 12 2017 101...
Page 104: ...20 Scheduled operations 102 723 0016 F90 01 12 2017...
Page 112: ...21 DMD DMD Board CLGA DMD heatsink elements 110 723 0016 F90 01 12 2017...
Page 132: ...24 Lens shift assembly 130 723 0016 F90 01 12 2017...
Page 134: ...25 Prism Housing Image 25 5 132 723 0016 F90 01 12 2017...