background image

ENABLING BRIGHT OUTCOMES

MDRC-2324 (option HPEW)

MDRC-2324 (option HTEW)

MDRC-2324 (option HNEW)

MDRC-2324 (option HTIB)

MDRC-2324 (option HNIB)

MDRC-2324 (option STIB)

MDRC-2324 (option SNIB)

User guide

24-inch clinical display

Eonis

Summary of Contents for Eonis MDRC-2324

Page 1: ...RIGHT OUTCOMES MDRC 2324 option HPEW MDRC 2324 option HTEW MDRC 2324 option HNEW MDRC 2324 option HTIB MDRC 2324 option HNIB MDRC 2324 option STIB MDRC 2324 option SNIB User guide 24 inch clinical dis...

Page 2: ...Factory FIMI S r l Via Saul Banfi 1 21047 Saronno Italy Registered office FIMI S r l Via Vittor Pisani 6 20124 Milano Italy www barco com en support www barco com...

Page 3: ...color space 16 3 9 QAWeb presets 16 3 10 Display functions 16 3 11 White point selection 17 3 12 Analog video settings 18 3 13 Power save mode 18 3 14 OSD menu language 18 3 15 OSD menu orientation 19...

Page 4: ...R5910550 00 Eonis 4...

Page 5: ...ck MDRC 2324 option STIB Standard brightness PCAP touchscreen Internal power supply Black MDRC 2324 option HNIB High brightness None Internal power supply Black MDRC 2324 option HTIB High brightness P...

Page 6: ...ated user guides Keep your original packaging It is designed for this display and is the ideal protection during transport and storage 1 2 Product overview Front 2 3 4 1 Image 1 1 1 Display stand 2 Co...

Page 7: ...Image 1 2 MDRC 2324 option SNIB STIB HNIB and HTIB 8 9 1 2 3 4 6 7 5 Image 1 3 MDRC 2324 option HNEW HTEW and HPEW 1 Kensington security slot 2 USB B 2 0 upstream connector 3 USB A 2 0 downstream con...

Page 8: ...R5910550 00 Eonis 8 Welcome...

Page 9: ...ARNING Sufficient expertise is required to install this equipment All devices and complete setup must be tested before taking into operation CAUTION When the display is assembled in the medical system...

Page 10: ...USB host to make use of QAWeb or any of the display USB downstream connectors e g to connect a keyboard mouse or other peripheral Image 2 2 3 MDRC 2324 option SNIB STIB HNIB and HTIB Connect the main...

Page 11: ...WARNING The display must be in its highest position before it can be properly pivoted The standard orientation of the video input is landscape If you use the display in portrait mode make sure you cha...

Page 12: ...R5910550 00 Eonis 12 T W Lmin Lmax Image 2 6 Installation...

Page 13: ...13 R5910550 00 Eonis Operation 3...

Page 14: ...derstand pixel technology LCD displays use technology based on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit w...

Page 15: ...menu 3 Enter the Power Status LED submenu 4 Change the behavior of the power status LED as desired and confirm 3 5 Control wheel locking unlocking About To avoid unwanted or accidental activation of t...

Page 16: ...disabled To select sRGB color space 1 Bring up the OSD main menu 2 Navigate to the Adjustments menu 3 Select sRGB and confirm 3 9 QAWeb presets About QAWeb presets Display function white point selecti...

Page 17: ...g room into account The available reading room options are Darkroom Selects DICOM calibrated function optimized for darkroom conditions 0 50 Lux Office Selects DICOM function optimized for office cond...

Page 18: ...og menu 3 Adjust one of the available analog video settings as desired 3 13 Power save mode About power save mode Enabling power save mode on your MDRC 2324 will optimize the display lifetime by autom...

Page 19: ...About factory reset A factory reset allows you to fully restore the display to its original factory setting To perform a factory reset 1 Bring up the OSD main menu 2 Navigate to the Adjustments Setti...

Page 20: ...R5910550 00 Eonis 20 Operation...

Page 21: ...21 R5910550 00 Eonis Maintenance 4...

Page 22: ...quid may cause damage to internal electronics Instead apply the liquid to a cleaning cloth To clean the display Clean the display using a sponge cleaning cloth or soft tissue lightly moistened with a...

Page 23: ...23 R5910550 00 Eonis Important information 5...

Page 24: ...th air or with oxygen or nitrous oxide The equipment shall not be operable when the air oxygen content is above 25 Non patient care equipment Equipment primarily for use in a health care facility that...

Page 25: ...t receptacle marked hospital only or hospital grade These instructions need to be marked either on the equip or on a tag on the power cord Do not overload wall outlets and extension cords as this may...

Page 26: ...a qualified technician to restore the product to normal operation If the equipment has been dropped or the cabinet has been damaged If the product exhibits a distinct change in performance indicating...

Page 27: ...lists the names and contents of toxic and or hazardous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry...

Page 28: ...the materials used for manufacturing makes it easy to wipe and clean and therefore suitable to be used for various applications in hospitals and other medical environments where procedures for freque...

Page 29: ...etermined by turning the device off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the se...

Page 30: ...uding interference that may cause undesired operation Interference can be determined by turning the equipment off and on If this equipment does cause harmful interference to or suffer from harmful int...

Page 31: ...ommended that the MDRC 2324 be powered from an uninterruptible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m Not applicable 2 Power frequency magnetic fields s...

Page 32: ...pplicable EC directives Indicates compliance with Part 15 of the FCC rules Class A or Class B E346057 Indicates the device is approved according to the UL regulations for Canada and US Indicates the d...

Page 33: ...ate yy xx Indicates the temperature limitations3 for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue number Warning dangerous...

Page 34: ...ure limits4 to which the device can be safely exposed when being stored 85 5 x yy Indicates the range4 of humidity to which the device can be safely exposed when being stored 106 kPa 50 kPa xx yyy Ind...

Page 35: ...Yes Gray imaging Yes Bit depth 30 bit Viewing angle H V 178 Ambient light presets Yes reading room selection Front sensor Yes Front Consistency Sensor Maximum luminance 600 cd m DICOM calibrated lumin...

Page 36: ...n HNEW 4 4 kg MDRC 2324 option HTEW 5 5 kg MDRC 2324 option HPEW 5 4 kg Net weight packaged MDRC 2324 option SNIB and HNIB 8 8 kg including optional accessories MDRC 2324 option STIB and HTIB 9 8 kg i...

Page 37: ...deo cable 1x USB cable 1x printed User Guide English 1x system disc containing MediCal QAWeb software graphics board drivers and translations of the User Guide Mains cables 1x UK 1x EUR 1x USA 1x PRC...

Page 38: ...istered office FIMI S r l Via Vittor Pisani 6 20124 Milano Italy Factory FIMI S r l Via Saul Banfi 1 21047 Saronno Italy www barco com R5910550 00 2019 02 13 FIMI S r l Vittor Pisani 6 20124 Milano It...

Reviews: