4. Lamp & lamp house
4.6
Resetting the lamp parameters
C
AUTION
:
The “LAMP INFO” parameters MUST be updated after each installation of an xenon lamp inside
the Lamp House. Neglecting this update will result in poor performance and short life time of the xenon lamp.
How to reset the lamp parameters?
1. Start up the projector but do not ignite the lamp.
2. Go via the
Communicator
touch panel to the menu “
Installation
” > “
Lamp
” > “
Lamp information
”.
3. While the
Lamp information
window is displayed, tap on
Reset
(1).
A reset message is displayed (2).
4. Tap on
Select
(3) to display a list of possible article numbers (4). Select a article number (5) and tap
OK
(6).
The software will validate the selected article number (7).
5. Fill out the serial number of the lamp (8).
6. Click
Reset
(9).
Image 4-24
Reset lamp info
C
AUTION
:
For more information about using the Communicator Touch Panel consult the user’s guide of the
Communicator Touch Panel.
42
R59770495 DP2K-23B 30/04/2010
Summary of Contents for DP2K-23B
Page 1: ...DP2K 23B Installation manual R59770495 00 30 04 2010...
Page 6: ......
Page 37: ...4 Lamp lamp house Image 4 5 Remove lamp house R59770495 DP2K 23B 30 04 2010 31...
Page 47: ...4 Lamp lamp house 4 Reinstall the lamp cover of the projector R59770495 DP2K 23B 30 04 2010 41...
Page 78: ...7 Communicator Touch Panel 72 R59770495 DP2K 23B 30 04 2010...
Page 82: ...8 Starting up 76 R59770495 DP2K 23B 30 04 2010...
Page 90: ...9 Projector registration Image 9 9 Add new owner 84 R59770495 DP2K 23B 30 04 2010...
Page 110: ...10 Removal and installation of the projector covers 104 R59770495 DP2K 23B 30 04 2010...