2. General
2.1
Installation requirements
Environment conditions
Table below summarizes the physical environment in which the DP2K-23B digital projector may be safely operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10 °C (50 °F) to 35 °C (95 °F)
-15°C (5°F) to 60°C (140°F)
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the Light Pro-
cessor Unit.
Cooling requirements
The projector is fan cooled and must be installed with suf
fi
cient space aroundthe projector head, minimum 20 cm (8 inch) to ensure
suf
fi
cient air
fl
ow. It should be used in an area where the ambient temperature, as measured at the projectorair inlet , does not
35°C (+95°F).
The installation of an
exhaust system
is
MANDATORY
. The installed exhaust blower must remove an air volume of minimum
10
m
3
/min (350 CFM)
measured at the exhaust output of the projector.
Main Power requirements
The DP2K-23B operates from a nominal mono phase power net with a separate earth ground PE. The DP2K-23B requires 200-240
VAC, 50-60Hz, 30A at 200 VAC with a separate earth ground PE.
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than 4 mm² or 10 AWG, minimum 300V.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a quali
fi
ed electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
W
ARNING
:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet for removal
of all power from the unit
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an output voltage of 200-
240V at 50-60Hz and must be capable of delivering an output current of 5,5 amperes.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certi
fi
ed AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
:
The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The DP2K-23B does not have a built in UPS unit.
Exhaust outlet for external fan
The exhaust outlet has an output voltage of 200–240V at 50–60 Hz; switched and maximum 3 amperes is allowed.
The connection between the exhaust outlet and the external blower must be done with a certi
fi
ed AC power supply cord of minimum
0,75 mm² or 18 AWG and minimum 300V.
10
R59770495 DP2K-23B 30/04/2010
Summary of Contents for DP2K-23B
Page 1: ...DP2K 23B Installation manual R59770495 00 30 04 2010...
Page 6: ......
Page 37: ...4 Lamp lamp house Image 4 5 Remove lamp house R59770495 DP2K 23B 30 04 2010 31...
Page 47: ...4 Lamp lamp house 4 Reinstall the lamp cover of the projector R59770495 DP2K 23B 30 04 2010 41...
Page 78: ...7 Communicator Touch Panel 72 R59770495 DP2K 23B 30 04 2010...
Page 82: ...8 Starting up 76 R59770495 DP2K 23B 30 04 2010...
Page 90: ...9 Projector registration Image 9 9 Add new owner 84 R59770495 DP2K 23B 30 04 2010...
Page 110: ...10 Removal and installation of the projector covers 104 R59770495 DP2K 23B 30 04 2010...