2. General
Projector
Power requirements
DP2K-P
200-240 VAC, 50-60Hz, 30A at 200 VAC
DP4K-19B
200-240 VAC, 50-60Hz, 24A at 200 VAC
DP4K-23B
200-240 VAC, 50-60Hz, 30A at 200 VAC
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than 4 mm² or 10 AWG, minimum 300V.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a quali
fi
ed electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
W
ARNING
:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet for removal
of all power from the unit
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an output voltage of 200-
240V at 50-60Hz and must be capable of delivering an output current of 5,5 amperes.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certi
fi
ed AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
:
The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The B-series projector does not have a built in UPS unit.
Exhaust outlet for external fan
The exhaust outlet has an output voltage of 200–240V at 50–60 Hz; switched and maximum 3 amperes is allowed.
The connection between the exhaust outlet and the external blower must be done with a certi
fi
ed AC power supply cord of minimum
0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
:
The 200–240V power outlet (exhaust outlet) of the projector may not be used to provide power to
any other device than an external exhaust fan. Maximum allowed current : 3A.
Projector weight
Do not underestimate the weight of the B-series projector. The projector weights about ±133 kg (±293 lb.) without lens. Be sure that
the pedestal on which the projector has to be installed is capable of handling
fi
ve (5) times the complete load of the system.
Barco offers a pedestal for the B-series projector. This universal pedestal allows a solid and easy setup of the
projector. The universal pedestal has a separate compartment to install the UPS unit for the B-series projector.
Futhermore, the universal pedestal contains a standard 19” rack to build in the projector peripherals such as
alternative content switchers (e.g. ACS-2048)
10
R5905067 DPXK-19B/23B/P 17/09/2012
Summary of Contents for DP2K-19B
Page 6: ......
Page 14: ...1 Safety 8 R5905067 DPXK 19B 23B P 17 09 2012...
Page 22: ...2 General 16 R5905067 DPXK 19B 23B P 17 09 2012...
Page 32: ...3 Physical installation 26 R5905067 DPXK 19B 23B P 17 09 2012...
Page 62: ...5 Lenses lens holder 56 R5905067 DPXK 19B 23B P 17 09 2012...
Page 76: ...7 Communicator Touch Panel Image 7 8 Connections 70 R5905067 DPXK 19B 23B P 17 09 2012...
Page 78: ...8 Starting up 72 R5905067 DPXK 19B 23B P 17 09 2012...
Page 100: ...10 Removal and installation of the projector covers 94 R5905067 DPXK 19B 23B P 17 09 2012...
Page 120: ...A Specifications 114 R5905067 DPXK 19B 23B P 17 09 2012...
Page 124: ...B Pin configurations 118 R5905067 DPXK 19B 23B P 17 09 2012...