B. Pin configurations
B. PIN CONFIGURATIONS
Overview
•
About General Purpose Inputs & Outputs (GPIO)
•
gurations of the communication ports
•
B.1 About General Purpose Inputs & Outputs (GPIO)
General Purpose inputs
Eight (8) opto-isolated general purpose inputs are available. These inputs are used to trigger the execution of macro
fi
les. For more
explanation about the association of a macro to a GPI, consult the user guide of the Communicator touch panel.
Input voltage
The inputs can be directly driven from a TTL or CMOS output.
•
The shape of the pulse must be rectangular.
•
The duration of the pulse must be at least 1.6 milliseconds (shorter pulses are considered as a switch bounce)
•
Minimum voltage : V
min
= 3,3 V
•
Maximum voltage : V
max
= 24 V
External power supply
When interfacing with contact closure outputs, an external power supply needs to be provided. Depending upon the con
fi
guration a
suitable pull-up resistor needs to be added as well.
10k
820R
GPIn P
GPIn P
GPIn N
GPIn N
4.7V
Input to projector
Internal projector
1k1
+5V
to
+24V
10k
820R
GPIn P
GPIn P
GPIn N
GPIn N
4.7V
Input to projector
Internal projector
1k1
+5V
to
+24V
Image B-1
Left diagram: with pull-up resistor. Right diagram: without pull-up resistor.
Cables
When long cable connections are required the use of shielded cables with twisted pairs is recommended. One twisted pair is to be
assigned to each GP Input pair.
How to make the connection
When the power supply used to provide the DC voltage is isolated from ground (for example in the case of an AC adapter) it is
recommended that the minus pole of that power supply is connected to ground (or to the projector chassis). This will avoid high
common mode voltages at the projector GP Inputs. If that same power supply is used for other parts of the system, take care not to
create ground loops. In any case when shielded cables are used that shield should be connected to the projector chassis.
General Purpose outputs
Eight (8) opto-isolated outputs are available, where four are dedicated for TI. The other general purpose outputs can be controlled
via software.
About an output
The output can generate a falling edge, rising edge, toggle or continuous toggle.
R5905067 DPXK-19B/23B/P 17/09/2012
115
Summary of Contents for DP2K-19B
Page 6: ......
Page 14: ...1 Safety 8 R5905067 DPXK 19B 23B P 17 09 2012...
Page 22: ...2 General 16 R5905067 DPXK 19B 23B P 17 09 2012...
Page 32: ...3 Physical installation 26 R5905067 DPXK 19B 23B P 17 09 2012...
Page 62: ...5 Lenses lens holder 56 R5905067 DPXK 19B 23B P 17 09 2012...
Page 76: ...7 Communicator Touch Panel Image 7 8 Connections 70 R5905067 DPXK 19B 23B P 17 09 2012...
Page 78: ...8 Starting up 72 R5905067 DPXK 19B 23B P 17 09 2012...
Page 100: ...10 Removal and installation of the projector covers 94 R5905067 DPXK 19B 23B P 17 09 2012...
Page 120: ...A Specifications 114 R5905067 DPXK 19B 23B P 17 09 2012...
Page 124: ...B Pin configurations 118 R5905067 DPXK 19B 23B P 17 09 2012...