6. Lamps and lamp houses
6.1
Introduction
Lamp & lamp house
Normally the lamp house of the DP2K-12C/11CX projector is delivered with a mounted 2000 watt lamp. In case the xenon lamp is
delivered separately the lamp has to be installed on site by a quali
fi
ed service technician.
B
A
Image 6-1
A
Lamp house.
B
Xenon lamp.
The xenon lamp is packed in a protective container or wrapped in a protective cloth. Never remove this protective container or
protective cloth without wearing adequate protective clothing (face shield, clean leather glovers, welder’s jacket).
Image 6-2
Left: Xenon lamp in protective container. Right: Xenon lamp wrapped in protective cloth.
C
AUTION
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped or
otherwise mishandled. Whenever the lamp house, containing a xenon lamp, has to be dismantled or whenever
the protective container or cloth has to be removed from the xenon lamp, authorized protective clothing MUST
be worn!
Cathode adaptor
A cathode adaptor is required to mount the xenon lamp in the lamp house. The cathode adapter has to be mounted upon the cathode
side of the xenon lamp prior to mounting the lamp in the lamp house. The purpose of the cathode adapter is to position the arc of
the xenon lamp in the middle of the re
fl
ector inside the lamp house.
Image 6-3
Cathode adaptor (
R858100K
)
Supported xenon bulb lamps (without lamp house)
Lamp
Type
Order info
Osram xenon lamp of 2 kW
2kW DHP
R9855956
94
R5905043 DP2K-12C/11CX 19/02/2018
Summary of Contents for DP2K-12C
Page 1: ...DP2K 12C 11CX Service manual R5905043 15 19 02 2018...
Page 4: ......
Page 8: ...Table of contents 4 R5905043 DP2K 12C 11CX 19 02 2018...
Page 12: ...1 Safety 8 R5905043 DP2K 12C 11CX 19 02 2018...
Page 31: ...4 Troubleshooting 4 TROUBLESHOOTING R5905043 DP2K 12C 11CX 19 02 2018 27...
Page 32: ...4 Troubleshooting 28 R5905043 DP2K 12C 11CX 19 02 2018...
Page 96: ...5 Removal and installation of projector covers 92 R5905043 DP2K 12C 11CX 19 02 2018...
Page 121: ...6 Lamps and lamp houses Image 6 38 R5905043 DP2K 12C 11CX 19 02 2018 117...
Page 138: ...7 Cold mirror assembly 134 R5905043 DP2K 12C 11CX 19 02 2018...
Page 222: ...12 Card Cage 1 Image 12 11 218 R5905043 DP2K 12C 11CX 19 02 2018...
Page 225: ...12 Card Cage Image 12 15 Button unit removal R5905043 DP2K 12C 11CX 19 02 2018 221...
Page 281: ...15 Power input Image 15 13 Mains AC compartment cover R5905043 DP2K 12C 11CX 19 02 2018 277...
Page 282: ...15 Power input 278 R5905043 DP2K 12C 11CX 19 02 2018...
Page 306: ...18 Lamp power supply single module 302 R5905043 DP2K 12C 11CX 19 02 2018...
Page 340: ...21 Maintenance procedures 336 R5905043 DP2K 12C 11CX 19 02 2018...
Page 350: ...A Pin configurations 346 R5905043 DP2K 12C 11CX 19 02 2018...
Page 351: ...B Input formats B INPUT FORMATS R5905043 DP2K 12C 11CX 19 02 2018 347...
Page 352: ...B Input formats 348 R5905043 DP2K 12C 11CX 19 02 2018...